Literature DB >> 15057094

The role of proximal femoral support in stress development within hip prostheses.

Roy D Crowninshield1, William J Maloney, Douglas H Wentz, Danny L Levine.   

Abstract

Bone remodeling commonly associated with implant loosening may require revision total hip replacement when there is substantial proximal femoral bone loss. Additionally, the surgical exposure required to remove primary implants may alter the proximal femur's structure. As a result, in many revision hip situations the proximal femur provides compromised support for the revision femoral component. Stress analyses of the proximal femur with extensively porous-coated prosthetic femoral components show that proximomedial femoral bone loss, ununited femoral osteotomy, and periprosthetic fracture can result in significant elevation of stress within revision prosthetic components. The first principal stress within prosthetic components can, in proximal bone loss conditions, be elevated significantly above a revision prostheses' fatigue strength. Loss of proximomedial bone is predicted to increase stress within a revision component by as much as 82%. An unhealed transverse femoral fracture or osteotomy is predicted to more than double the stress within a revision femoral component. In revision total hip replacement, efforts directed toward the restoration of proximal femoral bone and the use of larger prostheses may contribute to avoiding prostheses fatigue fracture. Similarly, protected weightbearing in patients with ununited femoral osteotomies and periprosthetic fractures may be important to preventing prosthetic fracture.

Entities:  

Mesh:

Year:  2004        PMID: 15057094     DOI: 10.1097/00003086-200403000-00024

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  11 in total

1.  Fracture of Extensively Porous-Coated Cylindrical Femoral Stem Following Revision Total Hip Arthroplasty.

Authors:  Chao-Fan Zhang; Chun Hoi Yan; Fu Yuen Ng; Ping Keung Chan; Kwong Yuen Chiu
Journal:  Chin Med J (Engl)       Date:  2016-06-05       Impact factor: 2.628

2.  A biomechanical assessment of modular and monoblock revision hip implants using FE analysis and strain gage measurements.

Authors:  Habiba Bougherara; Rad Zdero; Suraj Shah; Milan Miric; Marcello Papini; Paul Zalzal; Emil H Schemitsch
Journal:  J Orthop Surg Res       Date:  2010-05-12       Impact factor: 2.359

3.  Influence of prosthesis design and implantation technique on implant stresses after cementless revision THR.

Authors:  Markus O Heller; Manav Mehta; William R Taylor; Dong-Yeong Kim; Andrew Speirs; Georg N Duda; Carsten Perka
Journal:  J Orthop Surg Res       Date:  2011-05-13       Impact factor: 2.359

4.  Fatigue fracture of a cemented Omnifit CoCr femoral stem: implant and failure analysis.

Authors:  Noah Bonnheim; Hannah Gramling; Michael Ries; Sanjai Shukla; Beatrice Iliescu; Lisa Pruitt
Journal:  Arthroplast Today       Date:  2017-08-02

5.  Fracture of cobalt chrome, fully-coat beaded femoral revision long stem, a clinical outcomes study.

Authors:  Chih-Hsiang Chang; Po-Chun Lin; Cheng-Min Shih; Chun-Chieh Chen; Pang-Hsin Hsieh; Hsin-Nung Shih
Journal:  Biomed J       Date:  2018-03-30       Impact factor: 4.910

6.  Minimal stress shielding with a Mallory-Head titanium femoral stem with proximal porous coating in total hip arthroplasty.

Authors:  Brad Ellison; Nicholas A Cheney; Keith R Berend; Adolph V Lombardi; Thomas H Mallory
Journal:  J Orthop Surg Res       Date:  2009-12-09       Impact factor: 2.359

7.  [Effectiveness of proximal femur reconstruction combined with total hip arthroplasty for Crowe type Ⅳ developmental dysplasia of hip].

Authors:  Lei Tang; Min Chen; Guoyuan Li; Zhengliang Luo; Xiaofeng Ji; Xiaoqi Zhang; Kerong Wu; Chen Zhu; Xifu Shang
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2020-06-15

8.  Fracture of Uncemented Revision Femoral Stems in three Arthroplasty Patients: A Case Series with three different brands.

Authors:  Rajiv Merchant; Ian Kelly; John Quinlan
Journal:  J Orthop Case Rep       Date:  2014 Oct-Dec

9.  REVISION TOTAL HIP ARTHROPLASTY USING A MODULAR CEMENTLESS DISTAL FIXATION PROSTHESIS: THE ZMR(®) HIP SYSTEM. CLINICAL AND RADIOGRAPHIC ANALYSIS OF 30 CASES.

Authors:  Richard Prazeres Canella; Paulo Gilberto Cimbalista de Alencar; Gerson Gandhi Ganev; Luiz Fernando de Vincenzi
Journal:  Rev Bras Ortop       Date:  2015-11-17

10.  Cortical Fenestration for Megaprosthesis Stem Revision.

Authors:  Vincent Y Ng; Philip Louie; Stephanie Punt; Ernest U Conrad Iii
Journal:  Open Orthop J       Date:  2017-03-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.