Fetal lung volume estimated by 3-dimensional ultrasonography and magnetic resonance imaging in cases with isolated congenital diaphragmatic hernia.

Rodrigo Ruano1, Laurence Joubin, Pascale Sonigo, Alexandra Benachi, Marie-Cecile Aubry, Jean-Christophe Thalabard, Francis Brunelle, Yves Dumez, Marc Dommergues.   

Abstract

OBJECTIVE: To assess the agreement of 3-dimensional ultrasonography and magnetic resonance imaging in estimating fetal lung volume in cases with isolated congenital diaphragmatic hernia.
METHODS: Fetal lung volume was measured in 11 cases of congenital diaphragmatic hernia (10 left and 1 right) by 3-dimensional ultrasonography and magnetic resonance imaging. These examinations were performed during the same week. The operators were blinded to each other's results. Intraclass correlation was used to evaluate the agreement between 3-dimensional ultrasonography and magnetic resonance imaging estimations of the ipsilateral, contralateral, and total fetal lung volume. A Bland-Altman graph was plotted to detect possible discordant observations.
RESULTS: The global intraclass correlation coefficient between magnetic resonance imaging and 3-dimensional ultrasonographic measurement of fetal lung volume was 0.94 (95% confidence interval, 0.78-0.98) with no outliers observed on the Bland-Altman plot.
CONCLUSIONS: There is a good agreement between 3-dimensional ultrasonography and magnetic resonance imaging for fetal lung volume estimation in cases with congenital diaphragmatic hernia.

Entities:  

Mesh:

Year:  2004        PMID: 15055782     DOI: 10.7863/jum.2004.23.3.353

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  4 in total

1.  Correlation between US and MRI for prenatal lung volumetry in diaphragmatic hernia, and use of Doppler to identify the ipsilateral lung cap.

Authors:  Amparo Castellote; Sandra Mencho; Elena Carreras; Teresa Higueras; Lina Cadavid; Joaquim Piqueras; Goya Enriquez
Journal:  Pediatr Radiol       Date:  2011-09-22

Review 2.  Three- and 4-dimensional ultrasound in obstetric practice: does it help?

Authors:  Luís F Gonçalves; Wesley Lee; Jimmy Espinoza; Roberto Romero
Journal:  J Ultrasound Med       Date:  2005-12       Impact factor: 2.153

3.  MR volumetry of brain and CSF in fetuses referred for ventriculomegaly.

Authors:  João Fernando Kazan-Tannus; Vandana Dialani; Milliam L Kataoka; Gloria Chiang; Henry A Feldman; Jeffrey S Brown; Deborah Levine
Journal:  AJR Am J Roentgenol       Date:  2007-07       Impact factor: 3.959

4.  The use of inversion mode and 3D manual segmentation in volume measurement of fetal fluid-filled structures: comparison with Virtual Organ Computer-aided AnaLysis (VOCAL).

Authors:  J P Kusanovic; J K Nien; L F Gonçalves; J Espinoza; W Lee; M Balasubramaniam; E Soto; O Erez; R Romero
Journal:  Ultrasound Obstet Gynecol       Date:  2008-02       Impact factor: 7.299