Value of transducer positions in the measurement of finger flexor tendon thickness by sonography.

Andrea Klauser1, Karl-Heinz Stadlbauer, Ferdinand Frauscher, Manfred Herold, Guenther Klima, Michael Schirmer, Dieter zur Nedden.   

Abstract

OBJECTIVE: To assess the value of 2 transducer positions for measurement of finger flexor tendon thickness by sonography.
METHODS: Flexor tendon thickness of the third finger was measured sonographically by 2 independent investigators in 20 healthy volunteers (n = 40 fingers) and in 4 cadaveric specimens (n = 4 fingers). Flexor tendon thickness was measured at histologic examination in the cadaveric specimens. We defined the area of the A1 annular pulley as position I and the area of the A2 annular pulley as position II. Sonographic measurements were performed in transverse (dorsovolar and radioulnar) and longitudinal planes. Interobserver and intraobserver variabilities were evaluated by each investigator performing 3 measurements at each position.
RESULTS: In position I, volunteers had flexor tendon thickness of 2.7 to 4.0 mm (mean +/- SD, 3.28 +/- 0.26 mm) longitudinally; transversally the thickness was 2.5 to 4.0 mm (mean, 3.34 +/- 0.29 mm) dorsovolar and 5.5 to 8.9 mm (mean, 7.34 +/- 0.71) radioulnar in position I. Position II revealed thickness of 3.2 to 4.2 mm (mean, 3.6 +/- 0.23 mm) longitudinally; transversally the thickness was 2.7 to 4.1 mm (mean, 3.4 +/- 0.27) dorsovolar and 4.3 to 6.8 mm (mean, 5.27 +/- 0.65) radioulnar. Interobserver and intraobserver variability for position I was better than for position II (P < .01 versus P < .05). Sonographic findings correlated excellently with histologic findings (r2 = 0.94).
CONCLUSIONS: Standardized transducer positions for sonographic measurements of finger flexor tendon thickness showed good interobserver and intraobserver variability. Position I was found to be more reliable than position II.

Mesh:

Year:  2004        PMID: 15055779     DOI: 10.7863/jum.2004.23.3.331

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  4 in total

1.  Tendon injuries of the hand.

Authors:  Volker Schöffl; Andreas Heid; Thomas Küpper
Journal:  World J Orthop       Date:  2012-06-18

2.  High-resolution ultrasound in the diagnosis of trigger finger and evaluation of response to steroid injection.

Authors:  Yutaka Mifune; Atsuyuki Inui; Ryosuke Sakata; Yoshifumi Harada; Fumiaki Takase; Masahiro Kurosaka; Takeshi Kokubu
Journal:  Skeletal Radiol       Date:  2016-10-08       Impact factor: 2.199

3.  Ultrasonographic assessment of clinically diagnosed trigger fingers.

Authors:  Hae-Rim Kim; Sang-Heon Lee
Journal:  Rheumatol Int       Date:  2009-10-23       Impact factor: 2.631

4.  Sonography of tendon pathology in the hand and wrist.

Authors:  Andrea B Rosskopf; Carlo Martinoli; Luca M Sconfienza; Salvatore Gitto; Mihra S Taljanovic; Riccardo Picasso; Andrea Klauser
Journal:  J Ultrason       Date:  2021-12-15
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.