Literature DB >> 15053656

Enzyme-linked immunosorbent assay for monitoring toxic dioxin congeners in milk based on a newly generated monoclonal anti-dioxin antibody.

Mitsunobu Okuyama1, Norihiro Kobayashi, Wakako Takeda, Takako Anjo, Yasuhiko Matsuki, Junichi Goto, Akira Kambegawa, Shinjiro Hori.   

Abstract

To develop an enzyme-linked immunosorbent assay (ELISA) for monitoring the toxicity due to polychlorinated dibenzo-p-dioxins and dibenzofurans contaminated in human breast milk, we have generated novel monoclonal antibodies using some haptenic derivatives linked to bovine serum albumin via the C-1 or C-2 position on the dioxin skeleton. BALB/c or A/J mice were repeatedly immunized with the immunogen, and spleen cells were fused with P3/NS1/1-Ag4-1 myeloma cells. After five fusion experiments, a hybridoma clone was established that secretes an antibody D9-36 group specifically recognizing the major toxic congeners, 2,3,7,8-tetrachlorodibenzo-p-dioxin (2,3,7,8-TCDD), 1,2,3,7,8-pentachlorodibenzo-p-dioxin, and 2,3,4,7,8-pentachlorodibenzofran. An ELISA is developed on the basis of the competitive and labeled-antigen format. The toxic congeners extracted from butter or milk specimens by a novel extraction cartridge and a peroxidase-labeled dioxin analogue were sequentially reacted with a fixed amount of D9-36 in the presence of Triton X-100. The bound fraction was captured on a microtiter plate, immobilizing a second antibody, and the enzyme activity was colorimetrically determined. This ELISA afforded a practical sensitivity (measurable range, 1-100 pg/assay; detection limit, 1.0 pg/assay as 2,3,7,8-TCDD equivalent). The assay values for milk and butter samples were in reasonable accordance with the sum of the toxicity-equivalent quantity of each congener, which had been determined by a high-resolution gas chromatography/high-resolution mass spectrometry method.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15053656     DOI: 10.1021/ac0303620

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

1.  An enzyme-linked immunosorbent assay for the determination of dioxins in contaminated sediment and soil samples.

Authors:  Jeanette M Van Emon; Jane C Chuang; Robert A Lordo; Mary E Schrock; Mikaela Nichkova; Shirley J Gee; Bruce D Hammock
Journal:  Chemosphere       Date:  2008-03-04       Impact factor: 7.086

2.  Immuno-detection of dioxins using a recombinant protein of aryl hydrocarbon receptor (AhR) fused with sfGFP.

Authors:  Walaa Faiad; Abdulsamie Hanano; Mohamed Maher Kabakibi; Abdul Qader Abbady
Journal:  BMC Biotechnol       Date:  2016-06-21       Impact factor: 2.563

Review 3.  Immunoanalysis methods for the detection of dioxins and related chemicals.

Authors:  Wenjing Tian; Heidi Qunhui Xie; Hualing Fu; Xinhui Pei; Bin Zhao
Journal:  Sensors (Basel)       Date:  2012-12-05       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.