Literature DB >> 15053648

Limits of recognition for simple vapor mixtures determined with a microsensor array.

Meng-Da Hsieh1, Edward T Zellers.   

Abstract

The "limit of recognition" (LOR) has been defined as the minimum concentration at which reliable individual vapor recognition can be achieved with a multisensor array, and methodology for determining the LORs of individual vapors probabilistically on the basis of sensor array response patterns has been reported. This article explores the problems of defining and evaluating LORs for vapor mixtures in terms of the absolute and relative component vapor concentrations, where the mixture must be discriminated from those component vapors and from the subset of possible lower-order component mixtures. Monte Carlo simulations and principal components regression analyses of an extant database of calibrated responses to a set of 16 vapors from an array of 6 diverse polymer-coated surface acoustic wave sensors are used to illustrate the approach and to examine trends in LOR values among the 120 possible binary mixtures and 560 possible ternary mixtures in the data set. At concentrations exceeding the LOD, 89% of the binary mixtures could be reliably recognized (<5% error) over some composite concentration range, while only 3% of the ternary mixtures could be recognized. Most binary mixtures could be recognized only if the constituent vapor relative concentration ratio, defined in terms of multiples of the LOD for each vapor, was < or =20. Correlations with the Euclidean distance(s) separating the normalized constituent vapor response vectors allow reasonably accurate predictions of the limiting recognizable mixture composition ranges for binary and ternary cases. Results are considered in the context of using microsensor arrays for vapor detection and recognition in microanalytical systems.

Entities:  

Year:  2004        PMID: 15053648     DOI: 10.1021/ac035294w

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  9 in total

Review 1.  Materials and transducers toward selective wireless gas sensing.

Authors:  Radislav A Potyrailo; Cheryl Surman; Nandini Nagraj; Andrew Burns
Journal:  Chem Rev       Date:  2011-09-07       Impact factor: 60.622

2.  Discrimination of complex mixtures by a colorimetric sensor array: coffee aromas.

Authors:  Benjamin A Suslick; Liang Feng; Kenneth S Suslick
Journal:  Anal Chem       Date:  2010-03-01       Impact factor: 6.986

3.  A colorimetric sensor array for identification of toxic gases below permissible exposure limits.

Authors:  Liang Feng; Christopher J Musto; Jonathan W Kemling; Sung H Lim; Kenneth S Suslick
Journal:  Chem Commun (Camb)       Date:  2010-02-11       Impact factor: 6.222

4.  Rapid identification of bacteria with a disposable colorimetric sensing array.

Authors:  James R Carey; Kenneth S Suslick; Keren I Hulkower; James A Imlay; Karin R C Imlay; Crystal K Ingison; Jennifer B Ponder; Avijit Sen; Aaron E Wittrig
Journal:  J Am Chem Soc       Date:  2011-04-27       Impact factor: 15.419

5.  An optoelectronic nose for the detection of toxic gases.

Authors:  Sung H Lim; Liang Feng; Jonathan W Kemling; Christopher J Musto; Kenneth S Suslick
Journal:  Nat Chem       Date:  2009-10       Impact factor: 24.427

Review 6.  Glove permeation of chemicals: The state of the art of current practice-Part 2. Research emphases on high boiling point compounds and simulating the donned glove environment.

Authors:  Sean Banaee; Shane S Que Hee
Journal:  J Occup Environ Hyg       Date:  2020-03-25       Impact factor: 2.155

7.  Determination of quasi-primary odors by endpoint detection.

Authors:  Hanxiao Xu; Koki Kitai; Kosuke Minami; Makito Nakatsu; Genki Yoshikawa; Koji Tsuda; Kota Shiba; Ryo Tamura
Journal:  Sci Rep       Date:  2021-06-08       Impact factor: 4.379

8.  Data-driven nanomechanical sensing: specific information extraction from a complex system.

Authors:  Kota Shiba; Ryo Tamura; Gaku Imamura; Genki Yoshikawa
Journal:  Sci Rep       Date:  2017-06-16       Impact factor: 4.379

9.  Molecular recognition using receptor-free nanomechanical infrared spectroscopy based on a quantum cascade laser.

Authors:  Seonghwan Kim; Dongkyu Lee; Xunchen Liu; Charles Van Neste; Sangmin Jeon; Thomas Thundat
Journal:  Sci Rep       Date:  2013-01-23       Impact factor: 4.379

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.