Literature DB >> 1505308

Immediate HbA1c results. Performance of new HbA1c system in pediatric outpatient population.

D G Marrero1, J L Vandagriff, R Gibson, S E Fineberg, N S Fineberg, C E Hiar, L E Crowley.   

Abstract

OBJECTIVE: This study compared the performance of a new device that uses an IA to measure HbA1c in 9 min with a 1-microliter capillary blood sample with AC and CE methods in both nondiabetic and diabetic pediatric patients. RESEARCH DESIGN AND METHODS: Two hundred seven pediatric subjects (103 nondiabetic, 104 with insulin-dependent diabetes mellitus) had HbA1c measured with the IA method and compared with total GHb values determined by AC and HbA1 by the CE method with the same whole-blood capillary aliquot. Glucose values were also obtained from the same blood samples.
RESULTS: Correlations and regression analyses show excellent correspondence between the three assays. The correlation between the AC and CE methods is 0.98 (P less than 0.001) with a slope of 1.615 +/- 0.0125 and intercept of 4.00 +/- 0.20. The correlation between the IA and AC methods is 0.99 (P less than 0.001) with a slope of 0.608 +/- 0.007 and intercept of 1.326 +/- 0.066. The correlation between the IA and CE methods is 0.97 (P less than 0.001), with a slope of 0.983 +/- 0.018 and intercept of 1.122 +/- 0.153. The average difference and average percentage difference between methods were also significant (P less than 0.001), reflecting the differences in GHb components measured. There was a significant correlation (P less than 0.001) between each method and glucose values (IA r = 0.72, AC r = 0.70, CE r = 0.73). Within-run precision for IA ranged from 1.7 to 3.5% and between-run precision 2.7 to 4.1%.
CONCLUSIONS: Study results suggest that the IA method gives extremely accurate and reliable values over the clinical range of interest. The instrument is small, portable, easy to use, and provides information within 9 min for both physicians and patients.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1505308     DOI: 10.2337/diacare.15.8.1045

Source DB:  PubMed          Journal:  Diabetes Care        ISSN: 0149-5992            Impact factor:   19.112


  7 in total

1.  A1cNow InView: a new simple method for office-based glycohemoglobin measurement.

Authors:  Amarbir Mattewal; Saleh Aldasouqi; David Solomon; Ved Gossain; Anthony Koller
Journal:  J Diabetes Sci Technol       Date:  2007-11

2.  Haemoglobin Graz, a novel haemoglobin variant.

Authors:  W J Schnedl; E C Reisinger; T R Pieber; M Neubauer; E Balaun; G J Krejs; P Hopmeier
Journal:  Diabetologia       Date:  1995-01       Impact factor: 10.122

3.  Treating prepartum depression to improve infant developmental outcomes: a study of diabetes in pregnancy.

Authors:  Tassy Hayden; Dana C Perantie; Billy D Nix; Linda D Barnes; Dorothea J Mostello; William L Holcomb; Dragan M Svrakic; Jeffrey F Scherrer; Patrick J Lustman; Tamara Hershey
Journal:  J Clin Psychol Med Settings       Date:  2012-09

Review 4.  Hemoglobin variants recently detected in Austria.

Authors:  W J Schnedl; E C Reisinger; R W Lipp; G J Krejs; P Hopmeier
Journal:  Ann Hematol       Date:  1995-10       Impact factor: 3.673

5.  Translating the Diabetes Prevention Program into the community. The DEPLOY Pilot Study.

Authors:  Ronald T Ackermann; Emily A Finch; Edward Brizendine; Honghong Zhou; David G Marrero
Journal:  Am J Prev Med       Date:  2008-10       Impact factor: 5.043

6.  Effect of self-efficacy on weight loss: a psychosocial analysis of a community-based adaptation of the diabetes prevention program lifestyle intervention.

Authors:  Laura M Hays; Emily A Finch; Chandan Saha; David G Marrero; Ronald T Ackermann
Journal:  Diabetes Spectr       Date:  2014-11

7.  Reduced 10-year risk of coronary heart disease in patients who participated in a community-based diabetes prevention program: the DEPLOY pilot study.

Authors:  Elaine R Lipscomb; Emily A Finch; Edward Brizendine; Chandan K Saha; Laura M Hays; Ronald T Ackermann
Journal:  Diabetes Care       Date:  2008-12-23       Impact factor: 19.112

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.