A randomized trial of suprasternal palpation to determine endotracheal tube position in neonates.

Alok Jain1, Neil N Finer, Saskia Hilton, Wade Rich.   

Abstract

OBJECTIVE: To compare suprasternal palpation, a previously described bedside technique, with standard chest radiography for correct positioning of the endotracheal tube (ETT) in newborn infants. STUDY
DESIGN: A randomized single-blinded study in an academic medical center. Preterm and term newborn infants requiring intubation were eligible, provided that they had not had their initial chest roentgenogram (CXR). Infants were randomized to ETT palpation and non-adjustment (Controls), or to ETT palpation and adjustment (Treatment), following digital palpation of the ETT tip in the suprasternal notch. ETT position was considered correct when only the tip of the ETT was palpable in the suprasternal notch. ETT position by CXR was blindly assessed by an experienced pediatric radiologist.
RESULTS: Fifty-five infants were enrolled in the delivery room or neonatal intensive care unit. Correct tube placements improved from 48% pre-study to 85 and 93% in the Control and Treatment arms, respectively. The majority of incorrect estimations were that the ETT position using palpation was judged to be too low when it was, in fact, in correct position, as noted in 11 infants. ETT palpation had a 70% concordance with the position determined by CXR. No difficulties or complications were associated with the use of suprasternal palpation.
CONCLUSIONS: Suprasternal palpation is a simple, safe, teachable, method of confirming ETT position in neonates when CXR is unavailable, and may especially helpful during neonatal resuscitation prior to surfactant administration.

Entities:  

Mesh:

Year:  2004        PMID: 15050762     DOI: 10.1016/j.resuscitation.2003.11.010

Source DB:  PubMed          Journal:  Resuscitation        ISSN: 0300-9572            Impact factor:   5.262


  3 in total

1.  T-piece gas flow palpation as a clinical indicator of endotracheal intubation in neonates.

Authors:  Peter M Moran; Colin Patrick Hawkes; Eugene Michael Dempsey; C Anthony Ryan
Journal:  Eur J Pediatr       Date:  2012-12-28       Impact factor: 3.183

2.  Optimal Line and Tube Placement in Very Preterm Neonates: An Audit of Practice.

Authors:  Daragh Finn; Hannah Kinoshita; Vicki Livingstone; Eugene M Dempsey
Journal:  Children (Basel)       Date:  2017-11-17

3.  Randomised trial estimating length of endotracheal tube insertion using gestational age or nasal-tragus length in newborns: a study protocol.

Authors:  Abdul Razak; Maheer Faden; Jameel Alghamdi; Abdulaziz Binmanee; Abdullah Hawash Alonazi; Anas Hamdoun; Saud Almugaiteeb; Waseemoddin Patel; Hamdi Katar; Fabian Lora; Abdullah Alismail; Adrian Lavery; Ibrahim Hamama; Noura Alsaleem; Manal Alshaikh; Lama Alrasheed; Omar Aldibasi
Journal:  BMJ Open       Date:  2022-01-19       Impact factor: 2.692

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.