Literature DB >> 15050261

Day to day variability of the dark-adapted pupil diameter.

Sandra M Brown1, Arshad M Khanani, Ke Tom Xu.   

Abstract

PURPOSE: To determine the individual variability of the dark-adapted pupil diameter over 2 testing sessions using a standardized dark-adaptation protocol.
SETTING: Texas Tech University Health Sciences Center, Lubbock, Texas, USA.
METHODS: In this prospective observational cohort study, 40 volunteers with no history of ocular disease, surgery, or injury other than requirement for refractive correction were included. The right eye was tested. A standardized dark-adaptation protocol was used that controlled for accommodation and patient alertness. Infrared, still digital photographs were taken after 5 and 10 minutes of dark adaptation and analyzed independently by 2 investigators using digital-image software. Two test sessions were performed 1 to 7 days apart. Lifestyle factors such as sleep, diet, and exercise were not controlled.
RESULTS: The mean subject age was 31.5 years (range 20 to 49 years). There were 20 men; 27 subjects wore correction for myopia, and 13 wore no correction. The mean interval between test sessions was 2 days (range 1 to 7 days). The mean difference and 95% confidence intervals for pupil diameter difference between sessions were as follows: 5-minute readings, +0.032 mm (-0.030 to +0.094); 10-minute readings, -0.006 mm (-0.059 to +0.047); mean of 5- and 10-minute readings, +0.013 mm (-0.038 to +0.064). Using the paired t test, the pupil diameter did not differ significantly between sessions in 5-minute dark adaptation (P =.2980), 10-minute dark adaptation (P =.8263), or the mean (P =.6049).
CONCLUSION: Using a consistent dark-adaptation protocol that controlled for alertness, individuals aged 20 to 49 years showed no significant variation in dark-adapted pupil diameter when tested twice in 1 week.

Entities:  

Mesh:

Year:  2004        PMID: 15050261     DOI: 10.1016/j.jcrs.2003.09.060

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  2 in total

1.  Altered pupillary light response scales with disease severity in migrainous photophobia.

Authors:  Melissa M Cortez; Natalie A Rea; Lindsay A Hunter; Kathleen B Digre; K C Brennan
Journal:  Cephalalgia       Date:  2017-04-07       Impact factor: 6.292

Review 2.  Review on Centration, Astigmatic Axis Alignment, Pupil Size and Optical Zone in SMILE.

Authors:  Quan Liu; Xiaonan Yang; Limian Lin; Manli Liu; Haiqin Lin; Fang Liu; Yi Xie; Dennis S C Lam
Journal:  Asia Pac J Ophthalmol (Phila)       Date:  2019 Sep-Oct
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.