Literature DB >> 15045352

Cr(III) and Cr(VI) on-line preconcentration and determination with high performance flow flame emission spectrometry in natural samples.

J Posta1, A Gáspár, R Tóth, L Ombódi.   

Abstract

Methods for the on-line chromatographic preconcentration of Cr(III) and Cr(VI) have been developed. Cr(VI) has been preconcentrated on an RP C18 silica based column with tetrabutylammonium-bromide (TBABr) as ion-pairing agent. Specially for Cr(III) a new and effective preconcentration technique based on the sorption of Cr(III)-ions in a C18 column in presence of KH-phthalate has been developed. The efficiency of sample introduction into the atomic emission spectrometer could be improved by hydraulic high pressure nebulization. For the detection of chromium the acetylene/N(2)O flame has been used as a powerful emission spectrometric source. Applying these steps the detection limit (3sigma) could be improved to 25 pg/mL for Cr(III) and to 20 pg/mL for Cr(VI). The method has been applied for the chromium speciation in natural water samples.

Entities:  

Year:  1996        PMID: 15045352     DOI: 10.1007/s0021663550719

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  1 in total

1.  A new method for separation and determination of Cr(III) and Cr(VI) in water samples by high-performance liquid chromatography based on anion exchange stationary phase of ionic liquid modified silica.

Authors:  Susan Sadeghi; Ali Zeraatkar Moghaddam
Journal:  Environ Monit Assess       Date:  2015-11-03       Impact factor: 2.513