Literature DB >> 15042273

Application of heated electrodes operating in a non-isothermal mode for interference elimination with amperometric biosensors.

Carolin Lau1, Sabine Reiter, Wolfgang Schuhmann, Peter Gründler.   

Abstract

Heated electrodes were applied for the non-isothermal operation of amperometric glucose biosensors based on glucose oxidase immobilised on the electrode surface by entrapment within a polymer layer. The localised deposition of the polymer film under simultaneous entrapment of the enzyme was achieved by an electrochemically induced pH-modulation in the diffusion zone in front of the electrode, thus altering the solubility of the polymer chains. This non-manual sensor preparation protocol could be successfully used for the modification of a novel indirectly heated electrode. The non-isothermal operating mode allows working at the optimum temperature of the enzyme sensors without any thermal distortion of the bulk solution. Increased surface temperature of the sensor thus accelerates transport as well as kinetic processes, resulting in an enhanced amperometric signal. In the presence of interfering compounds such as ascorbic acid, the proposed technique allows use of the diverging thermal impact on the sensing process, for different electrochemically active compounds, for a deconvolution of the amperometric signal at different electrode temperatures. A calculation method for determination of glucose in the presence of one interfering compound is presented as a basis for a calculative interference elimination.

Entities:  

Year:  2004        PMID: 15042273     DOI: 10.1007/s00216-004-2585-2

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  4 in total

1.  High-temperature potentiometry: modulated response of ion-selective electrodes during heat pulses.

Authors:  Karin Y Chumbimuni-Torres; Chongdee Thammakhet; Michal Galik; Percy Calvo-Marzal; Jie Wu; Eric Bakker; Gerd-Uwe Flechsig; Joseph Wang
Journal:  Anal Chem       Date:  2009-12-15       Impact factor: 6.986

2.  Thermally Stable Improved First-Generation Glucose Biosensors based on Nafion/Glucose-Oxidase Modified Heated Electrodes.

Authors:  Ta-Feng Tseng; Yang-Li Yang; Min-Chieh Chuang; Shyh-Liang Lou; Michal Galik; Gerd-Uwe Flechsig; Joseph Wang
Journal:  Electrochem commun       Date:  2009-09-01       Impact factor: 4.724

3.  Diagnostic and Prognostic Characteristics of Circulating Free DNA Methylation Detected by the Electrochemical Method in Malignant Tumors.

Authors:  Li-Yue Sun; Zi-Ming Du; Yu-Ying Liu; Yan-Hong Li; Xiao-Min Liu; Ting Wang; Jian-Yong Shao
Journal:  Cancers (Basel)       Date:  2021-02-07       Impact factor: 6.639

4.  Towards an Electrochemical Immunosensor System with Temperature Control for Cytokine Detection.

Authors:  Julia Metzner; Katrin Luckert; Karin Lemuth; Martin Hämmerle; Ralf Moos
Journal:  Sensors (Basel)       Date:  2018-04-24       Impact factor: 3.576

  4 in total