Neither the accuracy nor the precision of thermal dilution cardiac output measurements is altered by acute tricuspid regurgitation in pigs.

Charles W Buffington1, Elisabet U M Nystrom.   

Abstract

UNLABELLED: Whether measurement of cardiac output using the thermal dilution technique (TDCO) is valid in the presence of tricuspid regurgitation (TR) is controversial. We assessed the accuracy and precision of the technique in pigs by comparison with data from an electromagnetic flowmeter on the aorta (EMCO). TR was created with sutures that immobilized the free-wall leaflets of the tricuspid valve, and cardiac output was adjusted with dobutamine to give values comparable to control measurements. TR reduced forward stroke volume from 17.2 to 12.6 mL/beat and caused the right atrium to dilate and pulse in synchrony with the right ventricle. Acute TR did not affect the linear regression relation between TDCO and EMCO and did not alter the correlation coefficient (r = 0.94 during both control and TR). These data demonstrate that acute TR does not affect the accuracy or precision of TDCO in pigs. IMPLICATIONS: Cardiac output is a valuable measurement that guides the medical care of patients with heart and lung disease. This study demonstrates that the thermal dilution technique of determining cardiac output is valid when acute tricuspid valve regurgitation is present in pigs.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15041567     DOI: 10.1213/01.ane.0000105923.09732.93

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  5 in total

1.  Can a NICO monitor substitute for thermodilution to measure cardiac output in patients with coexisting tricuspid regurgitation?

Authors:  Naka Imakiire; Takeshi Omae; Akira Matsunaga; Ryuzo Sakata; Yuichi Kanmura
Journal:  J Anesth       Date:  2010-05-19       Impact factor: 2.078

Review 2.  [Measurement of cardiac output].

Authors:  D A Reuter; A E Goetz
Journal:  Anaesthesist       Date:  2005-11       Impact factor: 1.041

3.  Accuracy of Doppler echocardiography in the hemodynamic assessment of pulmonary hypertension.

Authors:  Micah R Fisher; Paul R Forfia; Elzbieta Chamera; Traci Housten-Harris; Hunter C Champion; Reda E Girgis; Mary C Corretti; Paul M Hassoun
Journal:  Am J Respir Crit Care Med       Date:  2009-01-22       Impact factor: 21.405

4.  Comparison of echocardiographic indices of right ventricular systolic function and ejection fraction obtained with continuous thermodilution in critically ill patients.

Authors:  Romain Barthélémy; Xavier Roy; Tujia Javanainen; Alexandre Mebazaa; Benjamin Glenn Chousterman
Journal:  Crit Care       Date:  2019-09-13       Impact factor: 9.097

Review 5.  The contemporary pulmonary artery catheter. Part 2: measurements, limitations, and clinical applications.

Authors:  I T Bootsma; E C Boerma; T W L Scheeren; F de Lange
Journal:  J Clin Monit Comput       Date:  2021-03-01       Impact factor: 2.502