Literature DB >> 15041211

Piezoelectric biosensors for real-time monitoring of hybridization and detection of hepatitis C virus.

Petr Skládal1, Carla dos Santos Riccardi, Hideko Yamanaka, Paulo Inácio da Costa.   

Abstract

The piezoelectric quartz crystal resonators modified with oligonucleotide probes were used for detection of hepatitis C virus (HCV) in serum. The gold electrodes on either rough or smooth surface crystals were modified with a self-assembled monolayer of cystamine. After activation with glutaraldehyde, either avidin or streptavidin were immobilized and used for attachment of biotinylated DNA probes (four different sequences). Piezoelectric biosensors were used in a flow-through setup for direct monitoring of DNA resulting from the reverse transcriptase-linked polymerase chain reaction (RT-PCR) amplification of the original viral RNA. The samples of patients with hepatitis C were analyzed and the results were compared with the standard RT-PCR procedure (Amplicor test kit of Roche, microwell format with spectrophotometric evaluation). The piezoelectric hybridization assay was completed in 10 min and the same sensing surface was suitable for repeated use.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15041211     DOI: 10.1016/j.jviromet.2004.01.005

Source DB:  PubMed          Journal:  J Virol Methods        ISSN: 0166-0934            Impact factor:   2.014


  7 in total

Review 1.  Diagnosis of hepatitis via nanomaterial-based electrochemical, optical or piezoelectrical biosensors: a review on recent advancements.

Authors:  Soodabeh Hassanpour; Behzad Baradaran; Miguel de la Guardia; Amir Baghbanzadeh; Jafar Mosafer; Maryam Hejazi; Ahad Mokhtarzadeh; Mohammad Hasanzadeh
Journal:  Mikrochim Acta       Date:  2018-12-01       Impact factor: 5.833

Review 2.  Diagnostic tests for hepatitis C: recent trends in electrochemical immunosensor and genosensor analysis.

Authors:  Carolina V Uliana; Carla S Riccardi; Hideko Yamanaka
Journal:  World J Gastroenterol       Date:  2014-11-14       Impact factor: 5.742

Review 3.  Genosensors as an alternative diagnostic sensing approaches for specific detection of virus species: A review of common techniques and outcomes.

Authors:  Abouzar Babaei; Amir Pouremamali; Nastaran Rafiee; Hessamaddin Sohrabi; Ahad Mokhtarzadeh; Miguel de la Guardia
Journal:  Trends Analyt Chem       Date:  2022-05-19       Impact factor: 14.908

Review 4.  HCV Detection, Discrimination, and Genotyping Technologies.

Authors:  Shrikant Dashrath Warkad; Satish Balasaheb Nimse; Keum-Soo Song; Taisun Kim
Journal:  Sensors (Basel)       Date:  2018-10-12       Impact factor: 3.576

Review 5.  Biodiagnostics in an era of global pandemics-From biosensing materials to data management.

Authors:  Yoav Y Broza; Hossam Haick
Journal:  View (Beijing)       Date:  2021-06-18

Review 6.  Recent advances in application of biosensors in tissue engineering.

Authors:  Anwarul Hasan; Md Nurunnabi; Mahboob Morshed; Arghya Paul; Alessandro Polini; Tapas Kuila; Moustafa Al Hariri; Yong-kyu Lee; Ayad A Jaffa
Journal:  Biomed Res Int       Date:  2014-08-06       Impact factor: 3.411

7.  The detection of influenza A and B viruses in clinical specimens using a quartz crystal microbalance.

Authors:  Thamara M Peduru Hewa; Gregory A Tannock; David E Mainwaring; Sally Harrison; John V Fecondo
Journal:  J Virol Methods       Date:  2009-07-21       Impact factor: 2.014

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.