Literature DB >> 15040987

T1rho-weighted MRI using a surface coil to transmit spin-lock pulses.

Arijitt Borthakur1, Sridhar R Charagundla, Andrew Wheaton, Ravinder Reddy.   

Abstract

T1rho-weighted MRI is a novel basis for generating tissue contrast. However, it suffers from sensitivity to B1 inhomogeneity. First, excitation with a spatially varying B1 causes flip-angle artifacts and second, spin locking with an inhomogeneous B1 results in non-uniform T1rho contrast. In this study, we overcome the former complication with a specially designed spin-locking pulse sequence and we successfully obtain T1rho-weighted images with a surface coil. In this pulse sequence, the spin-lock pulse was divided into segments of equal duration and alternating phase. This "self-compensating" T1rho-preparatory pulse sequence was analyzed and the effect of an inhomogeneous B1 field was simulated using the Bloch equations. T1rho-weighted MR images of a phantom and a human knee joint in vivo were obtained on a clinical scanner with a surface coil to demonstrate the utility of the pulse sequence. The self-compensating T1rho-prepared pulses sequence resulted in substantially reduced image artifacts compared to the conventional, single-phase spin-lock pulse.

Entities:  

Mesh:

Year:  2004        PMID: 15040987     DOI: 10.1016/j.jmr.2004.01.007

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  6 in total

1.  Change of the cerebrospinal fluid volume during brain activation investigated by T(1rho)-weighted fMRI.

Authors:  Tao Jin; Seong-Gi Kim
Journal:  Neuroimage       Date:  2010-03-22       Impact factor: 6.556

2.  In vivo measurement of plaque burden in a mouse model of Alzheimer's disease.

Authors:  Arijitt Borthakur; Tamar Gur; Andrew J Wheaton; Matthew Corbo; John Q Trojanowski; Virginia M-Y Lee; Ravinder Reddy
Journal:  J Magn Reson Imaging       Date:  2006-11       Impact factor: 4.813

3.  Detection of changes in articular cartilage proteoglycan by T(1rho) magnetic resonance imaging.

Authors:  Andrew J Wheaton; George R Dodge; Arijitt Borthakur; J Bruce Kneeland; H Ralph Schumacher; Ravinder Reddy
Journal:  J Orthop Res       Date:  2005-01       Impact factor: 3.494

4.  Cardiac 17O MRI: toward direct quantification of myocardial oxygen consumption.

Authors:  Kyle S McCommis; Xiang He; Dana R Abendschein; Pradeep M Gupte; Robert J Gropler; Jie Zheng
Journal:  Magn Reson Med       Date:  2010-06       Impact factor: 4.668

5.  Characterization of non-hemodynamic functional signal measured by spin-lock fMRI.

Authors:  Tao Jin; Seong-Gi Kim
Journal:  Neuroimage       Date:  2013-04-22       Impact factor: 6.556

6.  Endogenous assessment of chronic myocardial infarction with T(1ρ)-mapping in patients.

Authors:  Joep W M van Oorschot; Hamza El Aidi; Sanne J Jansen of Lorkeers; Johannes M I H Gho; Martijn Froeling; Fredy Visser; Steven A J Chamuleau; Pieter A Doevendans; Peter R Luijten; Tim Leiner; Jaco J M Zwanenburg
Journal:  J Cardiovasc Magn Reson       Date:  2014-12-20       Impact factor: 5.364

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.