Literature DB >> 15032894

Crowns cemented on crown preparations lacking geometric resistance form. Part II: effect of cement.

Periklis Proussaefs1.   

Abstract

PURPOSE: This study evaluated the effect of different cements on resistance to dislodgment of crowns cemented on preparations lacking geometric resistance form.
MATERIALS AND METHODS: A preparation that offered no geometric resistance form, with 20 degrees total occlusal convergence (TOC), 0.9 mm wide shoulder finish line, and a 2.5 mm axial wall height was created on an ivorine tooth using a milling machine. Ten metal test specimen die replicas and 10 standardized metal crowns with recipient sites for the application of external forces through a universal testing machine were fabricated. The crowns were cemented on the dies under 5 and 10 kg external loads, the marginal openings measured, loaded to dislodgment, and cleaned of cement. The process was repeated using zinc oxide and eugenol (ZOE), zinc phosphate (ZPh), resin modified glass ionomer (RMGI), and composite resin (CR) cements.
RESULTS: Marginal openings under 5 kg cementation loads were 74.63 (+/-15.04) for ZOE, 75.98 (+/-18.20) microm for ZPh, 98.58 (+/-22.62) microm for RMGI, and 105.82 (+/-20.07) microm for CR cements respectively; under 10 kg cementation loads they were 57.62 (+/-15.86) microm, 59.55 (+/-15.41) microm, 95.00 (+/-19.52) microm, 101.30 (+/-12.52) microm respectively. Oblique dislodgment forces, measured with a Universal testing machine, were 40.18 (+/- 6.76) N for ZOE, 215.65 (+/-45.79) N for ZPh, 165.43 (+/-19.53) N for RMGI, and 181.54 (+/-30.75) N for CR respectively when crowns were cemented under 5 kg loads. The corresponding values for 10 kg loads were 38.62 (+/-4.19), 274.86 (+/-54.22), 139.70 (+/-21.71), and 160.40 (+/-21.21) respectively. Only zinc phosphate cement produced statistically enhanced resistance when crowns were cemented under 10 kg force (p value = 0.035).
CONCLUSIONS: Under the conditions of the present study only crowns cemented with zinc phosphate displayed increased resistance to dislodgment on preparations lacking resistance form.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15032894     DOI: 10.1111/j.1532-849X.2004.04008.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  9 in total

1.  Precision of fit: zirconia three-unit fixed dental prostheses.

Authors:  Florian Beuer; Michael Naumann; Wolfgang Gernet; John A Sorensen
Journal:  Clin Oral Investig       Date:  2008-09-04       Impact factor: 3.573

2.  The selection criteria of temporary or permanent luting agents in implant-supported prostheses: in vitro study.

Authors:  Angel Alvarez-Arenal; Ignacio Gonzalez-Gonzalez; Hector deLlanos-Lanchares; Aritza Brizuela-Velasco; Joseba Ellacuria-Echebarria
Journal:  J Adv Prosthodont       Date:  2016-04-21       Impact factor: 1.904

3.  In vitro evaluation of fracture strength of zirconia restoration veneered with various ceramic materials.

Authors:  Yu-Sung Choi; Sung-Hun Kim; Jai-Bong Lee; Jung-Suk Han; In-Sung Yeo
Journal:  J Adv Prosthodont       Date:  2012-08-28       Impact factor: 1.904

4.  Marginal and internal fit of CAD/CAM and slip-cast made zirconia copings.

Authors:  Kianoosh Torabi Ardekani; Ahmad Hassan Ahangari; Leila Farahi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2012-06-06

5.  Marginal accuracy of computer-aided design- and computer-aided manufacturing-fabricated full-arch zirconia restoration.

Authors:  Niwut Juntavee; Issarawas Sirisathit
Journal:  Clin Cosmet Investig Dent       Date:  2018-02-15

6.  Marginal and internal fit of zirconia based fixed dental prostheses fabricated with different concepts.

Authors:  Florian Beuer; Natalie Korczynski; Antonia Rezac; Michael Naumann; Wolfgang Gernet; John A Sorensen
Journal:  Clin Cosmet Investig Dent       Date:  2010-02-25

7.  Comparison of Conventional Methods and Laser-Assisted Rapid Prototyping for Manufacturing Fixed Dental Prostheses: An In Vitro Study.

Authors:  Giorgio Pompa; Stefano Di Carlo; Francesca De Angelis; Maria Paola Cristalli; Susanna Annibali
Journal:  Biomed Res Int       Date:  2015-10-21       Impact factor: 3.411

8.  Fracture Strength of Aged Monolithic and Bilayer Zirconia-Based Crowns.

Authors:  Deborah Pacheco Lameira; Wilkens Aurélio Buarque e Silva; Frederico Andrade e Silva; Grace M De Souza
Journal:  Biomed Res Int       Date:  2015-10-21       Impact factor: 3.411

9.  Internal accuracy of digitally fabricated cross-arch yttria-stabilized tetragonal zirconia polycrystalline prosthesis.

Authors:  Niwut Juntavee; Issarawas Sirisathit
Journal:  Clin Cosmet Investig Dent       Date:  2018-07-09
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.