Literature DB >> 15032360

Countering matrix effects in environmental liquid chromatography-electrospray ionization tandem mass spectrometry water analysis for endocrine disrupting chemicals.

Tom Benijts1, Riet Dams, Willy Lambert, André De Leenheer.   

Abstract

In recent years, despite the increasing success of liquid chromatography (LC) coupled to tandem mass spectrometry (MS), reports on matrix susceptibility have shown the limitations of the this powerful analytical technique. Matrix effects (MEs) result from co-eluting residual matrix components affecting the ionization efficiency of target analytes and can lead to erroneous results. The present work evaluates the matrix effect of environmental water samples on 35 endocrine disrupting chemicals (EDCs) in negative and positive LC-ESI-MS/MS. It was shown that mobile-phase additives could significantly influence matrix effects. Addition of acids resulted in a severe signal suppression (average ME%: <65%), and 1 mM ammonium formate increased the average ME% to 84%. The importance of an efficient sample clean-up and internal standardization also was demonstrated. Cleaner extracts resulted in reduced matrix effects (average ME%: 89%) and labeled internal standards proved to have a beneficial effect especially on signal reproducibility (average CV% 4.2% versus 2.6%). The results from the present work indicate that evaluation of matrix effects should become an integrated part of quantitative LC-ESI-MS/MS method development and validation.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15032360     DOI: 10.1016/j.chroma.2003.12.022

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  12 in total

1.  Comparison of matrix effects in HPLC-MS/MS and UPLC-MS/MS analysis of nine basic pharmaceuticals in surface waters.

Authors:  Jet C Van De Steene; Willy E Lambert
Journal:  J Am Soc Mass Spectrom       Date:  2008-02-07       Impact factor: 3.109

2.  Determination of glyphosate in surface water with high organic matter content.

Authors:  Vahur Toss; Ivo Leito; Sergei Yurchenko; Rene Freiberg; Anneli Kruve
Journal:  Environ Sci Pollut Res Int       Date:  2017-02-13       Impact factor: 4.223

Review 3.  Procedures of determining organic trace compounds in municipal sewage sludge-a review.

Authors:  Petra C Lindholm-Lehto; Heidi S J Ahkola; Juha S Knuutinen
Journal:  Environ Sci Pollut Res Int       Date:  2016-12-13       Impact factor: 4.223

4.  Drug detection and quantification directly from tissue using novel ionization methods for mass spectrometry.

Authors:  Beixi Wang; Chenelle L Dearring; James Wager-Miller; Ken Mackie; Sarah Trimpin
Journal:  Eur J Mass Spectrom (Chichester)       Date:  2015       Impact factor: 1.067

5.  Applications of Machine Learning to In Silico Quantification of Chemicals without Analytical Standards.

Authors:  Dimitri Panagopoulos Abrahamsson; June-Soo Park; Randolph R Singh; Marina Sirota; Tracey J Woodruff
Journal:  J Chem Inf Model       Date:  2020-05-20       Impact factor: 4.956

6.  Dried Blood Spot Methodology in Combination With Liquid Chromatography/Tandem Mass Spectrometry Facilitates the Monitoring of Teriflunomide.

Authors:  Aziz Filali-Ansary; Catherine Lunven; Sandrine Turpault; Yann-Joel Beyer; Amy OʼBrien; Astrid Delfolie; Neli Boyanova; Ger-Jan Sanderink; Francesca Baldinetti
Journal:  Ther Drug Monit       Date:  2016-08       Impact factor: 3.681

Review 7.  A review of the pharmaceutical exposome in aquatic fauna.

Authors:  Thomas H Miller; Nicolas R Bury; Stewart F Owen; James I MacRae; Leon P Barron
Journal:  Environ Pollut       Date:  2018-04-10       Impact factor: 8.071

8.  Assessing Binary Mixture Effects from Genotoxic and Endocrine Disrupting Environmental Contaminants Using Infrared Spectroscopy.

Authors:  Camilo L M Morais; Richard F Shore; M Glória Pereira; Francis L Martin
Journal:  ACS Omega       Date:  2018-10-17

9.  Classification and Temporal Variability in Urinary 8-oxodG and 8-oxoGuo: Analysis by UHPLC-MS/MS.

Authors:  Ziqi Li; Yuan Yao; Yanfei Zhang; Yining Zhang; Yijun Shao; Chuanxi Tang; Weidong Qu; Ying Zhou
Journal:  Sci Rep       Date:  2019-06-03       Impact factor: 4.379

10.  Melamine Sponge Functionalized with Urea-Formaldehyde Co-Oligomers as a Sorbent for the Solid-Phase Extraction of Hydrophobic Analytes.

Authors:  María Teresa García-Valverde; Theodoros Chatzimitakos; Rafael Lucena; Soledad Cárdenas; Constantine D Stalikas
Journal:  Molecules       Date:  2018-10-10       Impact factor: 4.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.