Literature DB >> 15023389

Simplified intensity-modulated arc therapy for dose escalated prostate cancer radiotherapy.

G Bauman1, E Gete, J Z Chen, E Wong.   

Abstract

Simplified intensity-modulated arc therapy (SIMAT) employs forward planned, conformal, and avoidance arc combinations with dynamic multileaf collimation (MLC) as a simpler alternative to other forms of intensity-modulated radiotherapy (IMRT). In this work, we compare SIMAT with 4-field (4F) and 6-field (6F) 3D conformal radiation therapy (CRT) for prostate cancer treatment. Prostate, seminal vesicle, bladder, and rectum were contoured on the CT images of 10 patients being planned for radiotherapy. Two planning target volumes (PTV) were defined: PTV1 (prostate + seminal vesicles + 1.0-cm margin) and PTV2 (prostate + 1.0-cm margin). SIMAT, 4F, and 6F plans were generated with a prescription dose of 78 Gy to prostate and 54 Gy to the seminal vesicles. Differences in the 3 techniques in terms of target and rectal coverage were compared. In addition, dose distributions of the SIMAT plans were verified with measurements in a phantom. Mean dose to PTV2 (4F, 76 Gy; 6F, 78 Gy; SIMAT, 76 Gy) and the dose delivered to 95% of the target volume (D(95)) were similar between the 3-techniques. Target conformity was better with SIMAT. Mean dose and calculated NTCP for the rectum were lower for SIMAT than those for 4F and 6F plans (4F 55.6 Gy vs. 6F 49.0 Gy vs. SIMAT 42.7 Gy). Mean dose to femoral heads was lower for the 4F technique vs. 6F and SIMAT techniques (4F 44.5 Gy vs. 6F 48.9 Gy vs. SIMAT 49.5 Gy). In-phantom measurement demonstrated good agreement between the plans and SIMAT treatments delivered in phantom. We concluded that SIMAT demonstrates advantages over 4F and 6F in terms of target conformity mean rectal dose and NTCP with good reproducibility in phantom. On the basis of this analysis, we have commenced a clinical pilot study of SIMAT for prostate cancer radiotherapy.

Entities:  

Mesh:

Year:  2004        PMID: 15023389     DOI: 10.1016/j.meddos.2003.09.003

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  1 in total

1.  Comparison of intensity-modulated radiotherapy and forward-planning dynamic arc therapy techniques for prostate cancer.

Authors:  Mohamed Metwaly; Awaad Mousa Awaad; El-Sayed Mahmoud El-Sayed; Abdel Sattar Mohamed Sallam
Journal:  J Appl Clin Med Phys       Date:  2008-10-24       Impact factor: 2.102

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.