Literature DB >> 15019444

Determination of polymerization shrinkage stress by means of a photoelastic investigation.

Claus-Peter Ernst1, Gerrit R Meyer, Kerstin Klöcker, Brita Willershausen.   

Abstract

OBJECTIVE: This study examined the polymerization stress of different established composite resins (Tetric Ceram, Vivadent; EsthetX, Surefil, Dentsply/DeTrey; Clearfil AP-X, Clearfil Photo Posterior, Kuraray; Prodigy Condensable, sds Kerr; Filtek P 60, 3M ESPE; Solitaire 2, Heraeus-Kulzer) by means of a photo-elastic investigation and investigated six new, experimental composite resins, which have been claimed to exhibit less polymerization shrinkage (InTen-S, Vivadent; K 112, K 051, Dentsply/DeTrey; Compox, Pluto, Hermes 3M ESPE).
METHODS: Cylindrical cavities (phi 5 mm) in Araldit B epoxide resin plates (40 x 40 x 3 mm3) were pretreated with the Rocatec system to ensure bonding of the composite resin. Ten composite resin specimens of each material, embedded in the Araldit plates, were exposed for 60 s (Elipar TriLight, Standard-mode, 800 mW/cm2). Polymerization contraction stress data (MPa) were calculated at 4 min and 24 h after exposure, based on the diameter of the isochromatic curves of first order obtained from the Araldit-plates. The statistical analysis was carried out with the Wilcoxon test (5% level).
RESULTS: After 24 h, the calculated mean polymerization stress values were 4.4+/-0.1 MPa for Tetric Ceram, 4.6+/-0.1 MPa for EsthetX, 3.7+/-0.1 MPa for Z 250, 4.6+/-0.1 MPa for Clearfil AP-X, 4.1+/-0.1 MPa for Prodigy Condensable, 4.0+/-0.1 MPa for Filtek P 60, 4.5+/-0.1 MPa for Surefil, 4,5+/-0.1 MPa for Clearfil Photo Posterior, 5.4+/-0.04 MPa for Solitaire 2, 3.2+/-0.1 MPa for In Ten-S, 3.9+/-0.1 MPa for K 112, 3.1+/-0.04 MPa for K 051, 3.2+/-0.1 MPa for Compox, and 2.0+/-0.1 MPa for Hermes.
CONCLUSIONS: The new and experimental composite resins In Ten-S, K 051, Compox, and Hermes showed significantly less polymerization shrinkage stress than the controls (p < 0.0005, Bonferroni correction). For the experimental material Pluto, no determination of isochromatic rings was possible.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15019444     DOI: 10.1016/S0109-5641(03)00109-X

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  7 in total

Review 1.  Polymerization shrinkage assessment of dental resin composites: a literature review.

Authors:  Dalia Kaisarly; Moataz El Gezawi
Journal:  Odontology       Date:  2016-08-19       Impact factor: 2.634

2.  Shrinkage Stresses Generated during Resin-Composite Applications: A Review.

Authors:  Luis Felipe J Schneider; Larissa Maria Cavalcante; Nick Silikas
Journal:  J Dent Biomech       Date:  2009-09-30

3.  Effect of cavity configuration (C factor) on the marginal adaptation of low-shrinking composite: a comparative ex vivo study.

Authors:  Motaz A Ghulman
Journal:  Int J Dent       Date:  2011-09-19

4.  Effect of an Extra Hydrophobic Resin Layer on Repair Shear Bond Strength of a Silorane-Based Composite Resin.

Authors:  Narmin Mohammadi; Mahmoud Bahari; Soodabeh Kimyai; Behnam Rahbani Nobar
Journal:  J Dent (Tehran)       Date:  2015-12

5.  Effect of different bleaching strategies on microhardness of a silorane-based composite resin.

Authors:  Mahmoud Bahari; Siavash Savadi Oskoee; Narmin Mohammadi; Mohammad Esmaeel Ebrahimi Chaharom; Mostafa Godrati; Ayda Savadi Oskoee
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2016-12-21

6.  The Influence of Low-Molecular-Weight Monomers (TEGDMA, HDDMA, HEMA) on the Properties of Selected Matrices and Composites Based on Bis-GMA and UDMA.

Authors:  Agata Szczesio-Wlodarczyk; Aleksander Polikowski; Michał Krasowski; Magdalena Fronczek; Jerzy Sokolowski; Kinga Bociong
Journal:  Materials (Basel)       Date:  2022-04-04       Impact factor: 3.623

7.  Effect of In-Office Carbamide Peroxide-Based Tooth Bleaching System on Wear Resistance of Silorane-Based and Methacrylate-Based Dental Composites.

Authors:  Masoumeh Hasani Tabatabaei; Sedigheh Sheikhzadeh; Hamidreza Ghasemi Monfared Rad; Ahmad Beygi; Hossein Bagheri
Journal:  J Dent (Tehran)       Date:  2015-08
  7 in total