Temporal variation in diabetic macular edema measured by optical coherence tomography.

Robert N Frank1, Laura Schulz, Kyohei Abe, Raymond Iezzi.   

Abstract

PURPOSE: To determine, by optical coherence tomography (OCT), whether there is a quantitative decrease in macular edema in diabetic subjects over the course of a day. STUDY
DESIGN: Observational case series. PARTICIPANTS: Ten subjects with diabetic macular edema in 1 or both eyes.
METHODS: Subjects were admitted to the hospital the evening before the study so that they would remain in the recumbent position until immediately before study measurements began. They then underwent 4 OCT measurements of macular thickness in both eyes, at 8:00 am, 11:00 am, 2:00 pm, and 5:00 pm. At each of these times, they also had refractions and visual acuity measurements using the Early Treatment Diabetic Retinopathy Study protocol. Macular thickness measurements determined by the Zeiss-Humphrey (Dublin, CA) optical coherence tomograph for each eye of each subject were plotted as a function of time. MAIN OUTCOME MEASURES: Temporal changes in retinal thickness in each of the 9 macular sectors defined by the OCT protocol and in the entire macula of each eye, averaged from all 9 sectors; temporal changes in refractive error and visual acuity.
RESULTS: Four of the 10 subjects showed consistent decreases in macular thickness over the course of the day in 1 or more of the retinal sectors in 1 or both eyes. When macular thickness values were averaged over all 9 sectors for all subjects, both eyes showed consistent declines in mean thickness throughout the day. By t test, the 8 am value in each eye was significantly higher (P<0.0005) than any of the 3 later values, which did not differ significantly from each other. However, comparison of all 4 values by analysis of variance showed no significant differences. With the exception of 1 subject, there were no consistent changes in refractive error or in best-corrected visual acuity over the course of the study.
CONCLUSIONS: This study, using quantitative OCT determinations, seems to confirm the much earlier report by Sternberg et al, which used more subjective methods, that macular edema might vary over the day. That the 8 am value, obtained just after waking, was higher than the 3 later values (highly significant by 1 test) suggests that the decrease in macular thickness is most likely due to the shift from recumbent to upright body position, although our study protocol did not exclude other possible mechanisms. Although changes in macular thickness over the course of the day did not occur in all subjects, therapeutic studies for macular edema that use OCT as an outcome measure should control for time of day when these measurements are carried out.

Entities:  

Mesh:

Year:  2004        PMID: 15019364     DOI: 10.1016/j.ophtha.2003.05.031

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  17 in total

1.  Effect of grid laser photocoagulation in diffuse diabetic macular edema in correlation to glycosylated haemoglobin (HbA1c).

Authors:  Katharina E Schmid; Beatrix Neumaier-Ammerer; Ulrike Stolba; Susanne Binder
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-04-07       Impact factor: 3.117

2.  Diurnal variation in retinal thickening measurement by optical coherence tomography in center-involved diabetic macular edema.

Authors:  Ronald P Danis; Adam R Glassman; Lloyd Paul Aiello; Andrew N Antoszyk; Roy W Beck; David J Browning; Antonio P Ciardella; James L Kinyoun; Timothy J Murtha; Trexler M Topping; Michel Shami; George S Sharuk; John A Wells
Journal:  Arch Ophthalmol       Date:  2006-12

3.  Spontaneous rodent models of diabetes and diabetic retinopathy.

Authors:  Cai-Rui Li; Shu-Guang Sun
Journal:  Int J Ophthalmol       Date:  2010-03-18       Impact factor: 1.779

4.  Diurnal variation of macular oedema in CRVO: prospective study.

Authors:  B Gupta; J Grewal; T Adewoyin; L Pelosini; T H Williamson
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-12-04       Impact factor: 3.117

5.  Optical coherence tomography measurements and analysis methods in optical coherence tomography studies of diabetic macular edema.

Authors:  David J Browning; Adam R Glassman; Lloyd P Aiello; Neil M Bressler; Susan B Bressler; Ronald P Danis; Matthew D Davis; Frederick L Ferris; Suber S Huang; Peter K Kaiser; Craig Kollman; Srinavas Sadda; Ingrid U Scott; Haijing Qin
Journal:  Ophthalmology       Date:  2008-08       Impact factor: 12.079

6.  Macular and retinal nerve fiber layer thickness in Japanese measured by Stratus optical coherence tomography.

Authors:  Toshiyuki Oshitari; Katsuhiro Hanawa; Emiko Adachi-Usami
Journal:  Clin Ophthalmol       Date:  2007-06

7.  Capillary pressure may predict preclinical changes in the eye.

Authors:  K M Gooding; J E Tooke; H von Lany; M Mitra; R Ling; C I Ball; D Mawson; K Skinner; A C Shore
Journal:  Diabetologia       Date:  2010-06-06       Impact factor: 10.122

Review 8.  [Optical coherence tomography for macular edema. Classification, quantitative assessment, and rational usage in the clinical practice].

Authors:  U Schaudig; F Scholz; R-C Lerche; G Richard
Journal:  Ophthalmologe       Date:  2004-08       Impact factor: 1.059

9.  Normal macular thickness measurements in healthy eyes using Stratus optical coherence tomography.

Authors:  Annie Chan; Jay S Duker; Tony H Ko; James G Fujimoto; Joel S Schuman
Journal:  Arch Ophthalmol       Date:  2006-02

10.  Effect of light and diurnal variation on macular thickness in X-linked retinoschisis: a case series.

Authors:  Yair Rubinstein; Chen Weiner; Noa Chetrit; Hadas Newman; Idan Hecht; Nadav Shoshany; Eran Pras
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2020-01-02       Impact factor: 3.117