Literature DB >> 15017488

Esophageal function testing with combined multichannel intraluminal impedance and manometry: multicenter study in healthy volunteers.

Radu Tutuian1, Marcelo F Vela, Nagammapudur S Balaji, James L Wise, Joseph A Murray, Jeffrey H Peters, Steven S Shay, Donald O Castell.   

Abstract

BACKGROUND & AIMS: Combined multichannel intraluminal impedance and manometry (MII-EM) assesses esophageal function by simultaneous measurement of both pressure and bolus transit. Normative data for this method have not been published. The aim of this study was to establish normative data for combined MII-EM and to correlate liquid and viscous bolus transit by impedance with esophageal contractions by manometry.
METHODS: Forty-three normal volunteers recruited from 4 centers (15 women, 28 men; age range, 21-72 years) underwent combined MII-EM with a catheter containing 4 impedance-measuring segments and 4 solid-state pressure transducers. Each center recruited and analyzed subjects independently, according to pre-established criteria. Each subject received 20 x 5 mL swallows, 10 liquid and 10 viscous material. Tracings were analyzed manually for bolus presence time, bolus head advance time, segmental transit times, total bolus transit time, contraction amplitude, duration, and onset velocity.
RESULTS: Ninety-seven and four-tenths percent of manometrically normal liquid and 96.1% of manometrically normal viscous swallows had complete bolus transit by impedance. Almost half (47.2%) of manometrically ineffective liquid and 34.7% of ineffective viscous swallows had complete bolus transit, whereas 91.7% of manometric simultaneous liquid swallows and 54.5% of simultaneous viscous swallows had complete bolus transit. More than 93% of normal individuals had at least 80% complete liquid or at least 70% complete viscous bolus transit.
CONCLUSIONS: This study establishes normative data for combined MII-EM. Combined MII-EM may be a more sensitive tool in assessing esophageal function compared to standard manometry because impedance can distinguish different bolus transit patterns. Studies in patients with manometrically defined esophageal motility abnormalities should help clarify the functional importance of manometric ineffective and simultaneous swallows.

Entities:  

Mesh:

Year:  2003        PMID: 15017488     DOI: 10.1053/cgh.2003.50026

Source DB:  PubMed          Journal:  Clin Gastroenterol Hepatol        ISSN: 1542-3565            Impact factor:   11.382


  36 in total

1.  Weak peristalsis in esophageal pressure topography: classification and association with Dysphagia.

Authors:  Sabine Roman; Zhiyue Lin; Monika A Kwiatek; John E Pandolfino; Peter J Kahrilas
Journal:  Am J Gastroenterol       Date:  2010-10-05       Impact factor: 10.864

Review 2.  Impedance as an adjunct to manometric testing to investigate symptoms of dysphagia: What it has failed to do and what it may tell us in the future.

Authors:  T Omari; J Tack; N Rommel
Journal:  United European Gastroenterol J       Date:  2014-10       Impact factor: 4.623

3.  Gastroesophageal reflux disease after lung transplantation: pathophysiology and implications for treatment.

Authors:  Christopher S Davis; Vidya Shankaran; Elizabeth J Kovacs; James Gagermeier; Daniel Dilling; Charles G Alex; Robert B Love; James Sinacore; P Marco Fisichella
Journal:  Surgery       Date:  2010-08-21       Impact factor: 3.982

Review 4.  Technological insights: combined impedance manometry for esophageal motility testing-current results and further implications.

Authors:  Huan Nam Nguyen; Gerson Ricardo Souza Domingues; Frank Lammert
Journal:  World J Gastroenterol       Date:  2006-10-21       Impact factor: 5.742

Review 5.  Evaluation of esophageal motor disorders in the era of high-resolution manometry and intraluminal impedance.

Authors:  John E Pandolfino; William J Bulsiewicz
Journal:  Curr Gastroenterol Rep       Date:  2009-06

Review 6.  New esophageal function testing (impedance, Bravo pH monitoring, and high-resolution manometry): clinical relevance.

Authors:  Jason A Wilson; Marcelo F Vela
Journal:  Curr Gastroenterol Rep       Date:  2008-06

Review 7.  New technologies in the gastrointestinal clinic and research: impedance and high-resolution manometry.

Authors:  John E Pandolfino; Peter J Kahrilas
Journal:  World J Gastroenterol       Date:  2009-01-14       Impact factor: 5.742

8.  Laparoscopic antireflux surgery for gastroesophageal reflux disease after lung transplantation.

Authors:  P Marco Fisichella; Christopher S Davis; James Gagermeier; Daniel Dilling; Charles G Alex; Jennifer A Dorfmeister; Elizabeth J Kovacs; Robert B Love; Richard L Gamelli
Journal:  J Surg Res       Date:  2011-06-22       Impact factor: 2.192

9.  Severely disordered esophageal peristalsis is not a contraindication to laparoscopic Nissen fundoplication.

Authors:  Y W Novitsky; J Wong; K W Kercher; D E M Litwin; L L Swanstrom; B T Heniford
Journal:  Surg Endosc       Date:  2006-12-20       Impact factor: 4.584

10.  Parameters for quantifying bolus retention with high-resolution impedance manometry.

Authors:  Z Lin; F Nicodème; C-Y Lin; B Mogni; L Friesen; P J Kahrilas; J E Pandolfino
Journal:  Neurogastroenterol Motil       Date:  2014-04-22       Impact factor: 3.598

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.