Literature DB >> 15016601

Indoor air quality in ice skating rinks in Hong Kong.

H Guo1, S C Lee, L Y Chan.   

Abstract

Indoor air quality in ice skating rinks has become a public concern due to the use of propane- or gasoline-powered ice resurfacers and edgers. In this study, the indoor air quality in three ice rinks with different volumes and resurfacer power sources (propane and gasoline) was monitored during usual operating hours. The measurements included continuous recording of carbon monoxide (CO), carbon dioxide (CO(2)), total volatile organic compounds (TVOC), particulate matter with a diameter less than 2.5 microm (PM(2.5)), particulate matter with diameter less than 10 microm (PM(10)), nitric oxide (NO), nitrogen dioxide (NO(2)), nitrogen oxide (NO(x)), and sulfur dioxide (SO(2)). The average CO, CO(2), and TVOC concentrations ranged from 3190 to 6749 microg/m(3), 851 to 1329 ppm, and 550 to 765 microg/m(3), respectively. The average NO and NO(2) concentrations ranged from 69 to 1006 microg/m(3) and 58 to 242 microg/m(3), respectively. The highest CO and TVOC levels were observed in the ice rink which a gasoline-fueled resurfacer was used. The highest NO and NO(2) levels were recorded in the ice rink with propane-fueled ice resurfacers. The air quality parameters of PM(2.5), PM(10), and SO(2) were fully acceptable in these ice rinks according to HKIAQO standards. Overall, ice resurfacers with combustion engines cause indoor air pollution in ice rinks in Hong Kong. This conclusion is similar to those of previous studies in Europe and North America.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15016601     DOI: 10.1016/S0013-9351(03)00116-6

Source DB:  PubMed          Journal:  Environ Res        ISSN: 0013-9351            Impact factor:   6.498


  5 in total

1.  Particulate matter in the indoor and outdoor air of a gymnasium and a fronton.

Authors:  Célia Alves; Ana I Calvo; Liliana Marques; Amaya Castro; Teresa Nunes; Esther Coz; Roberto Fraile
Journal:  Environ Sci Pollut Res Int       Date:  2014-06-18       Impact factor: 4.223

2.  Exposure assessment of non-electric ice resurfacer operators in indoor ice rinks: a pilot study.

Authors:  Travis McLennon; Chun-Yip Hon
Journal:  Int J Occup Environ Health       Date:  2018-05-02

3.  Classifying Sources Influencing Indoor Air Quality (IAQ) Using Artificial Neural Network (ANN).

Authors:  Shaharil Mad Saad; Allan Melvin Andrew; Ali Yeon Md Shakaff; Abdul Rahman Mohd Saad; Azman Muhamad Yusof Kamarudin; Ammar Zakaria
Journal:  Sensors (Basel)       Date:  2015-05-20       Impact factor: 3.576

4.  Lung cancer and vehicle exhaust in trucking industry workers.

Authors:  Eric Garshick; Francine Laden; Jaime E Hart; Bernard Rosner; Mary E Davis; Ellen A Eisen; Thomas J Smith
Journal:  Environ Health Perspect       Date:  2008-05-30       Impact factor: 9.031

5.  Cause-specific mortality in the unionized U.S. trucking industry.

Authors:  Francine Laden; Jaime E Hart; Thomas J Smith; Mary E Davis; Eric Garshick
Journal:  Environ Health Perspect       Date:  2007-08       Impact factor: 9.031

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.