Neural space integrity of the lower cervical spine: effect of anterior lesions.

David J Nuckley1, Mark A Konodi, Geoffrey C Raynak, Randal P Ching, Jens R Chapman, Sohail K Mirza.   

Abstract

STUDY
DESIGN: A repeated measures study design was used to evaluate intervertebral foramen and spinal canal neural space integrity subsequent to sequential surgical anterior lesions of the lower cervical spine in a human cadaver model.
OBJECTIVE: To investigate the degree to which sequential ablation of anterior vertebral elements places the neural structures at risk of injury. SUMMARY OF BACKGROUND DATA: Classic instability management utilizing functional-structural criteria has been widely examined associating specific lesions or pathologies to a degree of mechanical instability. Unfortunately, these studies have not assessed the neuroprotective role of the vertebral column.
METHODS: Eight human cadaveric lower cervical spines were instrumented with transducers to measure geometrical changes in the intervertebral foramen and spinal canal. Sequential lesions were performed anteriorly on the anterior and middle column structures (C4-C5 disc and C5 vertebra), and their effects on neural space integrity and range of motion were measured under physiologic loading.
RESULTS: Range of motion significantly increased with successively more destructive lesions, whereas the spinal canal exhibited few changes. Intervertebral foramen integrity was statistically reduced for corpectomy (66% intact), hemivertebrectomy (62% intact) and full vertebrectomy (57% intact) lesions when loaded in concomitant extension and ipsilateral bending (4 Nm).
CONCLUSIONS: Lesions more extensive than a surgical discectomy have significant effects on the cervical neural foramens specifically when the spine is placed in extension, ipsilateral bending, and coupled ipsilateral bending and extension. Our study establishes a quantitative relationship between the risk of neural structure compression and anterior lesions of the spinal column under physiologic loading.

Entities:  

Mesh:

Year:  2004        PMID: 15014274     DOI: 10.1097/01.brs.0000115132.49734.33

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  3 in total

1.  Motion is reduced in the unstable spine with the use of mechanical devices for bed transfers.

Authors:  Calvin T Hu; Christian P Dipaola; Bryan P Conrad; Marybeth Horodyski; Gianluca Del Rossi; Glenn R Rechtine
Journal:  J Spinal Cord Med       Date:  2013-01       Impact factor: 1.985

2.  The 6-plus-person lift transfer technique compared with other methods of spine boarding.

Authors:  Gianluca Del Rossi; Marybeth H Horodyski; Bryan P Conrad; Christian P Di Paola; Matthew J Di Paola; Glenn R Rechtine
Journal:  J Athl Train       Date:  2008 Jan-Mar       Impact factor: 2.860

3.  Artificial disc and vertebra system: a novel motion preservation device for cervical spinal disease after vertebral corpectomy.

Authors:  Jun Dong; Meng Lu; Teng Lu; Baobao Liang; Junkui Xu; Jie Qin; Xuan Cai; Sihua Huang; Dong Wang; Haopeng Li; Xijing He
Journal:  Clinics (Sao Paulo)       Date:  2015-07-01       Impact factor: 2.365

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.