Literature DB >> 15013544

Comparison of stability of absorbable and titanium plate and screw fixation for sagittal split ramus osteotomy.

Dogan Dolanmaz1, Sina Uckan, Kubilay Isik, Haci Saglam.   

Abstract

Six unembalmed adult sheep mandibles were stripped of all soft tissues and sectioned at the midline. Each side had a sagittal split ramus osteotomy (SSRO) and was advanced 5 mm. Six of the hemimandibles were fixed with four-hole extended titanium miniplates and titanium screws, and the other six were fixed with four-hole extended absorbable plates and absorbable screws. All specimens were mounted in a servohydraulic testing unit, and a range of forces (0-140 N) was applied. Displacement of each proximal segment was recorded at 10 N increments from 0 to 140 N. Values for the two groups were compared using the Mann-Whitney U-test, and significant differences in displacement were seen only at loads between 10 and 50 N. The results indicate that when absorbable miniplates are used intermaxillary fixation may be necessary to stabilise the bony fragments in the early postoperative period.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15013544     DOI: 10.1016/S0266-4356(03)00234-1

Source DB:  PubMed          Journal:  Br J Oral Maxillofac Surg        ISSN: 0266-4356            Impact factor:   1.651


  5 in total

1.  Evaluation of the rigidity of sagittal split ramus osteotomy fixation using four designs of biodegradable and titanium plates--a numerical study.

Authors:  Safieh Albougha; Mhd Hassan Albogha; Mhd Ayham Darwich; Khaldoun Darwich
Journal:  Oral Maxillofac Surg       Date:  2015-03-19

2.  An image feature-based approach to automatically find images for application to clinical decision support.

Authors:  R Joe Stanley; Soumya De; Dina Demner-Fushman; Sameer Antani; George R Thoma
Journal:  Comput Med Imaging Graph       Date:  2010-12-08       Impact factor: 4.790

3.  The effect of botulinum toxin-A injection into the masseter muscles on prevention of plate fracture and post-operative relapse in patients receiving orthognathic surgery.

Authors:  Sung-Ho Shin; Yei-Jin Kang; Seong-Gon Kim
Journal:  Maxillofac Plast Reconstr Surg       Date:  2018-11-25

4.  Biocompatibility and Biocorrosion of Hydroxyapatite-Coated Magnesium Plate: Animal Experiment.

Authors:  Ho-Kyung Lim; Soo-Hwan Byun; Jae-Man Woo; Sae-Mi Kim; Sung-Mi Lee; Bong-Ju Kim; Hyoun-Ee Kim; Jung-Woo Lee; Soung-Min Kim; Jong-Ho Lee
Journal:  Materials (Basel)       Date:  2017-09-30       Impact factor: 3.623

5.  Biodegradable magnesium alloy (WE43) in bone-fixation plate and screw.

Authors:  Soo-Hwan Byun; Ho-Kyung Lim; Kwang-Hee Cheon; Sung-Mi Lee; Hyoun-Ee Kim; Jong-Ho Lee
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2020-02-12       Impact factor: 3.368

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.