Marie-Sophie Caubet1, Blandine Comte, Jean-Louis Brazier.
Abstract
A method using liquid chromatography coupled with mass spectrometry with an atmospheric pressure electrospray source was developed for analysis of labelled caffeine and fourteen of its metabolites in urine. Caffeine metabolic ratios were determined after an oral bolus of labelled caffeine in 20 healthy subjects with different characteristic CYP1A2 activity, relative to smoking habit and oral contraceptive intake. The use of labelled caffeine for the calculation of metabolic ratios avoided taking into account the important background of endogenous caffeine metabolites, very difficult to eliminate even after a specific diet. The selectivity and high sensitivity of mass spectrometry detection allowed urine collections for only a 3h period. Comparison between characteristic groups showed that labelled caffeine metabolic ratios were sensitive markers of changes in CYP1A2 activity.Entities:
Mesh:
Substances:
Year: 2004 PMID: 15013152 DOI: 10.1016/S0731-7085(03)00528-4
Source DB: PubMed Journal: J Pharm Biomed Anal ISSN: 0731-7085 Impact factor: 3.935