Literature DB >> 15011830

Venous pressure measurements in the superior and inferior vena cava: the influence of intra-abdominal pressure.

N Markou1, L Grigorakos, P Myrianthefs, E Boutzouka, M Rizos, P Evagelopoulou, H Apostolakos, G Baltopoulos.   

Abstract

BACKGROUND/AIMS: To investigate the relationship of pressure in the inferior vena cava (Pivc) with a) pressure in the superior vena cava (Psvc), b) intra-abdominal pressure as measured in the urinary bladder (Pcyst).
METHODOLOGY: A prospective study of 38 mechanically ventilated patients. Simultaneous measurements of Psvc, Pivc and Pcyst (151 sets of measurements) were performed. Measurements were divided in: Group A (Pcyst < 10 mmHg), group B (10 mmHg < or = Pcyst < 15 mmHg), group C (Pcyst > or = 15 mmHg). Statistical analysis was performed with paired t-test, Pearson correlation. Results are expressed in mean +/- SEM.
RESULTS: In Groups A and B, Psvc and Pivc were not significantly different and they were highly correlated (10.8+/-0.5 mmHg vs. 10.9+/-0.5 mmHg, r=0.93 for Group A and 14.4+/-0.7 mmHg vs. 14.7+/-0.6 mmHg, r=0.87 for Group B). Pcyst was significantly lower than Pivc in both groups. In Group C, Pivc was significantly higher than Psvc (18.9+/-0.7 mmHg vs. 16.4+/-0.7 mmHg). There was no significant difference between Pivc and Pcyst (19.2+/-0.6 mmHg). Pivc significantly correlated with Pcyst (r=0.78) and Psvc (r=0.7). A. When Pcyst > Psvc, Pivc was higher than Psvc (p<0.01). With Pcyst < 15 mmHg, no significant difference was found between Pcyst and Pivc and they were correlated (r=0.766, p<0.05). Pressures in the superior and inferior vena cava were also correlated (r=0.764, p<0.05). With Pcyst > or = 15 mmHg, Pivc was lower than Pcyst (p<0.01). It correlated highly with Pcyst (r=0.85, p<0.01) and less strongly with Psvc (r=0.701, p<0.01). B. When Pcyst < or = Psvc, no difference between Pivc and Psvc was observed. With Pcyst < 15 mmHg, Pivc was higher than Pcyst (p<0.01) and highly correlated with Psvc (r=0.932, p<0.01). Pivc also correlated with Pcyst (r=0.69, p<0.01). With Pcyst > or = 15 mmHg, Pivc was higher than Pcyst (p<0.01) and correlated with Psvc (r=0.74, p<0.01) and Pcyst (r=0.789, p<0.01).
CONCLUSIONS: Although Psvc and Pivc are interchangeable in the absence of an increased Pcyst, when Pcyst is high, measurements of Pivc are misleading. A Pcyst > Psvc results in a "waterfall" effect, and Pivc does not accurately reflect Psvc any more.

Entities:  

Mesh:

Year:  2004        PMID: 15011830

Source DB:  PubMed          Journal:  Hepatogastroenterology        ISSN: 0172-6390


  3 in total

1.  Does femoral venous pressure measurement correlate well with intrabladder pressure measurement? A multicenter observational trial.

Authors:  Bart L De Keulenaer; Adrian Regli; Wojciech Dabrowski; Vaxtang Kaloiani; Zsolt Bodnar; Javier Izura Cea; A Andrey Litvin; Wendy A Davis; Anne-Marie Palermo; Jan J De Waele; Manu L L N G Malbrain
Journal:  Intensive Care Med       Date:  2011-07-08       Impact factor: 17.440

2.  Increasing abdominal pressure with and without PEEP: effects on intra-peritoneal, intra-organ and intra-vascular pressures.

Authors:  Stephan M Jakob; Rafael Knuesel; Jyrki J Tenhunen; Richard Pradl; Jukka Takala
Journal:  BMC Gastroenterol       Date:  2010-07-04       Impact factor: 3.067

3.  Gas embolism under standard versus low pneumoperitoneum pressure during laparoscopic liver resection (GASES): study protocol for a randomized controlled trial.

Authors:  Danfeng Jin; Mingyue Liu; Jian Huang; Yongfeng Xu; Luping Liu; Changhong Miao; Jing Zhong
Journal:  Trials       Date:  2021-11-15       Impact factor: 2.279

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.