Study on the practical use of quantitative whole-body auto-radioluminography.

Kazuhiro Inazawa1, Masahiro Koike, Toshiro Yamaguchi.   

Abstract

The practical use of quantitative radioluminography (RLG) using reading system BAS 2000 (Fuji Photo Film Ltd., Tokyo, Japan) and STORM 820 (Molecular Dynamics, USA) was examined using a chemical matrix as an internal standard, which offers the benefits of being preservative, inexpensive, and easy to handle. The results were as follows: 1. As the water content is within the range of 65-80% for most organs and tissues, we selected a chemical matrix, Tissue-TEK containing 85% water, as a base for the preparation of a standard curve. 2. The calibration curve prepared using Tissue-Tek as the internal standard was compared with the calibration curve using liver paste preparations as the internal standard. The results showed good linearity in both cases, with almost no difference in the slopes of the two calibration curves. 3. The PSL-BG or MD counts/pixel-BG values of the lowest radioactivity concentration measured for small areas of the region of interest (ROI) showed large fluctuations with both BAS 2000 and STORM 820, but the fluctuation became less than 15% at above 25 mm(2) of ROI. 4. The value of dpm/g calculated using the calibration curve prepared from Tissue-Tex internal standards showed a very good correlation with the values of dpm/g obtained by scraping off the tissue from the remaining block and conducting measurements with a liquid scintillation counter.

Entities:  

Mesh:

Year:  2004        PMID: 15010294     DOI: 10.1016/j.yexmp.2003.11.002

Source DB:  PubMed          Journal:  Exp Mol Pathol        ISSN: 0014-4800            Impact factor:   3.362


  3 in total

1.  Quantification of small molecule drugs in biological tissue sections by imaging mass spectrometry using surrogate tissue-based calibration standards.

Authors:  Nozomi Takai; Yukari Tanaka; Hideo Saji
Journal:  Mass Spectrom (Tokyo)       Date:  2014-02-01

Review 2.  Spatially resolved absolute quantitation in thin tissue by mass spectrometry.

Authors:  Vilmos Kertesz; John F Cahill
Journal:  Anal Bioanal Chem       Date:  2021-04       Impact factor: 4.142

3.  Imaging Mass Spectrometry Revealed the Accumulation Characteristics of the 2-Nitroimidazole-Based Agent "Pimonidazole" in Hypoxia.

Authors:  Yukiko Masaki; Yoichi Shimizu; Takeshi Yoshioka; Fei Feng; Songji Zhao; Kenichi Higashino; Yoshito Numata; Yuji Kuge
Journal:  PLoS One       Date:  2016-08-31       Impact factor: 3.240