Literature DB >> 15008451

Retrospective clinical review of dental implants placed in a university training program.

David Kohavi1, Gilad Azran, Lior Shapira, Nardy Casap.   

Abstract

Many dental schools offer implant clinical training at the pre- and postdoctoral levels, but little has been published on the clinical outcomes of implants placed in those programs. A post-entry chart review was conducted of all Branemark and Taper-Lock implants placed in a university clinic by faculty-student teams. Case information was gathered on data reporting forms and entered into a computer spreadsheet program. Survival rates were calculated as percentages. Cumulative implant survival was 96% for all 303 implants placed. Eight of the 12 implants that failed were placed by 2 operators, only 1 of whom was in the early stages of implant training. Branemark implant survival was 94.9% (n = 198) at 36 months; failures occurred between stage 2 and 3 months (n = 8) in mandibles and after 12 months (n = 2) in maxillae. Taper-Lock implant survival was 98.1% (n = 105) at 24 months; no mandibular failures occurred, but maxillary failures occurred before stage 2 (n = 1) and after 12 months of loading (n = 1). Taper-Lock implants exhibited a slightly higher (3.2%) cumulative survival rate at 24 months compared to Branemark implants. Differences in the numbers of implants placed (105 vs 198) and follow-up times (24 months vs 36 months) may have skewed the comparative results of Taper-Lock and Branemark implants, respectively, in this study. Implant survival for both systems was similar at 24 months of follow-up, and clinician experience did not appear to be an influencing variable on implant survival.

Mesh:

Substances:

Year:  2004        PMID: 15008451     DOI: 10.1563/1548-1336(2004)030<0023:RCRODI>2.0.CO;2

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  2 in total

1.  Retrospective study to identify associations between clinician training and dental implant outcome and to compare the use of MATLAB with SAS.

Authors:  Jyoti Sonkar; Pooja Maney; Qingzhao Yu; Archontia Palaiologou
Journal:  Int J Implant Dent       Date:  2019-08-09

2.  Accuracy of implant surgery with surgical guide by inexperienced clinicians: an in vitro study.

Authors:  Takeshi Toyoshima; Hideaki Tanaka; Masanori Sasaki; Eiji Ichimaru; Yasushi Naito; Yasuyuki Matsushita; Kiyoshi Koyano; Seiji Nakamura
Journal:  Clin Exp Dent Res       Date:  2015-07-14
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.