Literature DB >> 15006332

An augmented fixation method for distal fibular fractures in elderly patients: a biomechanical evaluation.

Warren R Dunn1, Mark E Easley, Brent G Parks, Hans-Jörg Trnka, Lew C Schon.   

Abstract

This biomechanical investigation compared two fixation techniques for distal fibular fractures. Elderly cadaver lower extremities with simulated fibula fractures underwent fixation either with a plate and intramedullary Kirschner wires (K-wires) with or without the addition of three screws inserted through the four cortices of the fibula and the tibia. The specimens were axially loaded to body weight on a materials testing machine, and the supinated foot was externally rotated to failure. Displacement at the fracture site was monitored with an extensometer. Comparing the augmented technique with the technique without additional screws, mean stiffness was 460 +/- 100 and 320 +/- 200 N-mm/deg, strength at failure was 31 +/- 10 and 19 +/- 7 N-m, strength at 30 degrees external rotation was 15 +/- 5 and 10 +/- 6 N-m, and axial deformation was 0.04 +/- 0.06 mm and 0.10 +/- 0.04 mm, respectively. All differences were statistically significant.

Entities:  

Mesh:

Year:  2004        PMID: 15006332     DOI: 10.1177/107110070402500303

Source DB:  PubMed          Journal:  Foot Ankle Int        ISSN: 1071-1007            Impact factor:   2.827


  5 in total

1.  [Fractures of the ankle joint in elderly patients].

Authors:  Kajetan Klos; Paul Simons; Thomas Mückley; Bernhard Karich; Thorsten Randt; Matthias Knobe
Journal:  Unfallchirurg       Date:  2017-11       Impact factor: 1.000

2.  Locked plate fixation of the comminuted distal fibula: a biomechanical study.

Authors:  Neil J White; David T Corr; James P Wagg; Caeley Lorincz; Richard E Buckley
Journal:  Can J Surg       Date:  2013-02       Impact factor: 2.089

3.  Combined circular external fixation and open reduction internal fixation with pro-syndesmotic screws for repair of a diabetic ankle fracture.

Authors:  Zacharia Facaros; Crystal L Ramanujam; John J Stapleton
Journal:  Diabet Foot Ankle       Date:  2010-10-18

4.  Primary Arthrodesis for Diabetic Ankle Fractures.

Authors:  Caleb W Grote; William Tucker; Kelly Stumpff; Mitchell C Birt; Greg A Horton
Journal:  Foot Ankle Orthop       Date:  2020-03-24

5.  A biomechanical comparison study of a modern fibular nail and distal fibular locking plate in AO/OTA 44C2 ankle fractures.

Authors:  Paul J Switaj; Daniel Fuchs; Mohammed Alshouli; Avinash G Patwardhan; Leonard I Voronov; Muturi Muriuki; Robert M Havey; Anish R Kadakia
Journal:  J Orthop Surg Res       Date:  2016-09-15       Impact factor: 2.359

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.