Literature DB >> 15006060

Routine vascular control using the Hem-o-lok clip in laparoscopic nephrectomy: animal study and clinical application.

Sidney K H Yip1, Y H Tan, Christopher Cheng, H G Sim, Y M Lee, Christopher Chee.   

Abstract

BACKGROUND AND
PURPOSE: During laparoscopic nephrectomy (LPN), a stapling device is often used for vascular control, especially of the renal vein. Herein, we report our experience using a polymer clip (Hem-o-lok) for routine control of the vessels during LPN in the animal and clinical setting. PATIENTS AND METHODS: Fifty ablative and fifteen live-donor nephrectomies were performed in domestic pigs. Hem-o-lok clips (10 mm; Weck Closure System, Research Triangle Park, NC) were routinely used for vascular control. In addition, from January 2001 to July 2002, 46 patients underwent hand-assisted laparoscopic (HAL) (N=40) or laparoscopic (N=6) nephrectomy for renal disease or donor nephrectomy. Venous control was achieved solely by the Hem-o-lok clips where at least two clips were applied on the patient side. Arterial control was obtained by the Hem-o-lok clips either alone or in combination with the metal clips. The technical difficulty in obtaining vascular control, transfusion requirement, and clinical outcome were evaluated.
RESULTS: In the animal study (total 65 nephrectomies), individual vascular control was obtained by the Hem-o-lok clip in all cases except two, where vascular injury during dissection necessitated endoscopic stapling of renal hilum or open conversion. The warm ischemic time for animal donor kidney harvest was uniformly <2 minutes. In the clinical study, arterial control was obtained mostly by a combination of Hem-o-lok and metal clips. Venous control using the Hem-o-lok was successful in all 46 cases without any slipping of clips or uncontrolled bleeding. The mean operating time was 148 minutes. No open conversion was required. The transfusion rate was 6.5% (N=3), with none of the transfusions being related to inadequacy of vascular control using the Hem-o-lok. Major complications included deep vein thrombosis and postoperative retroperitoneal hemorrhage (same patient) and acute respiratory distress syndrome (N = 1). The mean postoperative stay was 5.2 days (range 1-20 days).
CONCLUSION: The Hem-o-lok is a reliable and economical device for vascular control in laparoscopic renal surgery.

Entities:  

Mesh:

Year:  2004        PMID: 15006060     DOI: 10.1089/089277904322836730

Source DB:  PubMed          Journal:  J Endourol        ISSN: 0892-7790            Impact factor:   2.942


  4 in total

1.  Laparoscopic vascular control techniques in donor nephrectomy: Effects on vessel length.

Authors:  Jonathan E Bernie; Chandru P Sundaram; Amy I Guise
Journal:  JSLS       Date:  2006 Apr-Jun       Impact factor: 2.172

2.  Computed tomography appearance of Hem-o-lok clips in patients who have undergone laparoscopic nephrectomy or nephroureterectomy.

Authors:  K Matsushita; S Matsubara; K Tsumura; I Taguchi; G Kawabata
Journal:  JSLS       Date:  2011 Oct-Dec       Impact factor: 2.172

3.  Transperitoneal laparoscopic left versus right live donor nephrectomy: Comparison of outcomes.

Authors:  Shrinivas Rudrapatna Pandarinath; Babulal Choudhary; Harvinder Singh Chouhan; Shivashankar Rudramani; Deepak Dubey
Journal:  Indian J Urol       Date:  2014-07

4.  Intra-abdominal resection of the umbilical vein and urachus of bovine fetuses using laparoscopy and celiotomy: surgical time and feasibility (cadaveric study).

Authors:  Heytor Jales Gurgel; Simon Silva de Sousa; João Pedro Monteiro Barroso; Gabrielle Patrizi Braga Vasconcelos; Daniele Lira Dos Santos; Luiz Henrique Vilela Araújo; Loise Araújo de Sousa; Gabriela Melo Alves Dos Santos; Kayan da Cunha Rossy; Verena Siqueira da Silva; Camila do Espirito Santo Fernandes; Barbara da Conceição Guilherme; Helaine Freitas Miranda; Carla Rozilene Guimarães Silva; Rodrigo Dos Santos Albuquerque; Luisa Pucci Bueno Borges; Gilson Ferreira de Araújo; Renata Sitta Mariano Landers; Pedro Paulo Maia Teixeira; Francisco Décio de Oliveira Monteiro
Journal:  Sci Rep       Date:  2021-03-05       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.