Literature DB >> 15005333

Planar system for magnetic induction conductivity measurement using a sensor matrix.

C H Riedel1, M Keppelen, S Nani, R D Merges, O Dössel.   

Abstract

In this study the performance of an axial gradiometer sensor for magnetic induction tomography was investigated and the results of measurements to determine the precision and sensitivity of the sensor were undertaken. In the first part of the study a single gradiometer sensor was used and the noise and drift were measured for two excitation current values at a single frequency of 600 kHz. The variations of the real and imaginary received signal components with conductivity were then obtained for samples with 0-5 S m(-1). Both sets of measurements were repeated using two different forms of capacitive shielding. In the second part of the study the results of preliminary measurements obtained with a 2 x 2 planar matrix of axial gradiometers are given. The results of a simulation of a similar matrix using a commercial electromagnetic field calculation programme are also presented for comparison. For the sample utilized, the sensor output showed a linear variation with conductivity for the imaginary component of 0.033 mV S(-1) m using an excitation current of 316 mA at 600 kHz. No apparent correlation with conductivity for the real component was observed. The noise and drift of the imaginary component of the sensor output were 0.001 mV and 0.006 mV respectively, for the same excitation current. The results of the planar matrix measurements and simulations suggest that significant sensitivity is provided by using the measurement coils of the adjacent sensors. The measurement results however suggest that large improvements in the sensor noise and drift performance are required for these data to be of use.

Mesh:

Year:  2004        PMID: 15005333     DOI: 10.1088/0967-3334/25/1/043

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  5 in total

1.  Single-step 3-d image reconstruction in magnetic induction tomography: theoretical limits of spatial resolution and contrast to noise ratio.

Authors:  Hermann Scharfetter; Karl Hollaus; Javier Rosell-Ferrer; Robert Merwa
Journal:  Ann Biomed Eng       Date:  2006-10-10       Impact factor: 3.934

2.  The MAIN Shirt: a textile-integrated magnetic induction sensor array.

Authors:  Daniel Teichmann; Andreas Kuhn; Steffen Leonhardt; Marian Walter
Journal:  Sensors (Basel)       Date:  2014-01-09       Impact factor: 3.576

Review 3.  Advancements in transmitters and sensors for biological tissue imaging in magnetic induction tomography.

Authors:  Zulkarnay Zakaria; Ruzairi Abdul Rahim; Muhammad Saiful Badri Mansor; Sazali Yaacob; Nor Muzakkir Nor Ayub; Siti Zarina Mohd Muji; Mohd Hafiz Fazalul Rahiman; Syed Mustafa Kamal Syed Aman
Journal:  Sensors (Basel)       Date:  2012-05-29       Impact factor: 3.576

4.  A special phase detector for magnetic inductive measurement of cerebral hemorrhage.

Authors:  Gui Jin; Jian Sun; Mingxin Qin; Wanyou Guo; Qingguang Yan; Bin Peng; Wencai Pan
Journal:  PLoS One       Date:  2014-05-09       Impact factor: 3.240

Review 5.  Screening and Biosensor-Based Approaches for Lung Cancer Detection.

Authors:  Lulu Wang
Journal:  Sensors (Basel)       Date:  2017-10-23       Impact factor: 3.576

  5 in total