A primary field compensation scheme for planar array magnetic induction tomography.

S Watson1, A Morris, R J Williams, H Griffiths, W Gough.   

Abstract

In biomedical magnetic induction tomography (MIT), measurement precision may be improved by incorporating some form of primary field compensation/cancellation scheme. Schemes which have been described previously include gradiometric approaches and the use of 'back-off' coils. In each of these methods, however, the primary field cancellation was achieved only for a single transmitter/receiver combination. For the purpose of imaging, it would be desirable for a fully electronically scanned MIT system to provide a complete set of measurements, all with the primary field cancelled. A single channel suitable for incorporation into an MIT system with planar-array geometry is described. The transmitter is a 6-turn coil of wire 5 cm in diameter. The receiver is a surface mount inductor, of inductance 10 microH, mounted such that, in principle, no net primary field flux threads it. The results of measurements carried out with the single channel system suggest that the signal due to the primary excitation field can be reduced on average by a factor of 298 by the sensor geometry over the operating frequency range 1-10 MHz. The standard deviation and drift of the signal with the system adjusted for maximum primary field cancellation, expressed as a percentage of the signal when the receiver coil was rotated until its axis of sensitivity lay along the primary field, were 0.0009% and 0.009%, respectively. The filter time constant used was 30 ms.

Mesh:

Year:  2004        PMID: 15005321     DOI: 10.1088/0967-3334/25/1/031

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  4 in total

1.  Detection of cerebral hemorrhage in rabbits by time-difference magnetic inductive phase shift spectroscopy.

Authors:  Wencai Pan; Qingguang Yan; Mingxin Qin; Gui Jin; Jian Sun; Xu Ning; Wei Zhuang; Bin Peng; Gen Li
Journal:  PLoS One       Date:  2015-05-22       Impact factor: 3.240

2.  Detection and Elimination of Signal Errors Due to Unintentional Movements in Biomedical Magnetic Induction Tomography Spectroscopy (MITS).

Authors:  S Issa; H Scharfetter
Journal:  J Electr Bioimpedance       Date:  2018-12-31

Review 3.  Advancements in transmitters and sensors for biological tissue imaging in magnetic induction tomography.

Authors:  Zulkarnay Zakaria; Ruzairi Abdul Rahim; Muhammad Saiful Badri Mansor; Sazali Yaacob; Nor Muzakkir Nor Ayub; Siti Zarina Mohd Muji; Mohd Hafiz Fazalul Rahiman; Syed Mustafa Kamal Syed Aman
Journal:  Sensors (Basel)       Date:  2012-05-29       Impact factor: 3.576

4.  A special phase detector for magnetic inductive measurement of cerebral hemorrhage.

Authors:  Gui Jin; Jian Sun; Mingxin Qin; Wanyou Guo; Qingguang Yan; Bin Peng; Wencai Pan
Journal:  PLoS One       Date:  2014-05-09       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.