Advances in the determination of absorbed dose to water in clinical high-energy photon and electron beams using ionization chambers.

M Saiful Huq1, Pedro Andreo.   

Abstract

During the last two decades, absorbed dose to water in clinical photon and electron beams was determined using dosimetry protocols and codes of practice based on radiation metrology standards of air kerma. It is now recommended that clinical reference dosimetry be based on standards of absorbed dose to water. Newer protocols for the dosimetry of radiotherapy beams, based on the use of an ionization chamber calibrated in terms of absorbed dose to water, N(D,w), in a standards laboratory's reference quality beam, have been published by several national or regional scientific societies and international organizations. Since the publication of these protocols multiple theoretical and experimental dosimetry comparisons between the various N(D,w) based recommendations, and between the N(D,w) and the former air kerma (NK) based protocols, have been published. This paper provides a comprehensive review of the dosimetry protocols based on these standards and of the intercomparisons of the different protocols published in the literature, discussing the reasons for the observed discrepancies between them. A summary of the various types of standards of absorbed dose to water, together with an analysis of the uncertainties along the various steps of the dosimetry chain for the two types of formalism, is also included. It is emphasized that the NK-N(D,air) and N(D,w) formalisms have very similar uncertainty when the same criteria are used for both procedures. Arguments are provided in support of the recommendation for a change in reference dosimetry based on standards of absorbed dose to water.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15005158     DOI: 10.1088/0031-9155/49/4/r01

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Determination of electron energy, spectral width, and beam divergence at the exit window for clinical megavoltage x-ray beams.

Authors:  D L Sawkey; B A Faddegon
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

2.  Wax boluses and accuracy of EBT and RTQA radiochromic film detectors in radiotherapy with the JINR Phasotron proton beam.

Authors:  Dorota Maria Borowicz; Julian Malicki; Gennady Mytsin; Konstantin Shipulin
Journal:  Rep Pract Oncol Radiother       Date:  2013-07-02

3.  A novel nanometric DNA thin film as a sensor for alpha radiation.

Authors:  Atul Kulkarni; Byeonghoon Kim; Sreekantha Reddy Dugasani; Pranav Joshirao; Jang Ah Kim; Chirag Vyas; Vijay Manchanda; Taesung Kim; Sung Ha Park
Journal:  Sci Rep       Date:  2013       Impact factor: 4.379

4.  Study of the uncertainty in the determination of the absorbed dose to water during external beam radiotherapy calibration.

Authors:  Pablo Castro; Feliciano García-Vicente; Cristina Mínguez; Alejandro Floriano; David Sevillano; Leopoldo Pérez; Juan J Torres
Journal:  J Appl Clin Med Phys       Date:  2008-01-22       Impact factor: 2.102

5.  Comparison of IPSM 1990 photon dosimetry code of practice with IAEA TRS-398 and AAPM TG-51.

Authors:  Silvia Vargas Castrillón; Francisco Cutanda Henríquez
Journal:  J Appl Clin Med Phys       Date:  2009-01-14       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.