Literature DB >> 15004573

Comparison between clinical and ultrasound findings in patients with vitreous hemorrhage.

R Rabinowitz1, R Yagev, A Shoham, T Lifshitz.   

Abstract

PURPOSE: To ascertain the causes of vitreous hemorrhage and to determine the accuracy of ultrasound (U/S) in these cases, based on the degree of agreement between ultrasound and clinical findings.
METHODS: A chart review of 96 consecutive patients (106 eyes) with dense vitreous hemorrhage who underwent A- and B-scan U/S by one examiner between June 1996 and June 1999. U/S records were evaluated to determine the presence and exact distribution of areas of retinal detachment and the presence of posterior vitreous detachment, retinal tear, intraocular foreign body, or choroidal detachment. Clinical information was obtained from the medical records after the vitreous hemorrhage was reabsorbed or following vitreous surgery. Clinical and U/S findings were compared. False-positive and False-negative rates for U/S were calculated based on clinical findings.
RESULTS: In 37 eyes (35%) the vitreous hemorrhage was because of proliferative diabetic retinopathy and in 33 eyes (31%) because of ocular trauma. The false-positive rate for retinal detachment (retinal detachment by U/S without clinical confirmation) was 18.9% (seven of 37 eyes). Retinal tears were diagnosed and localized accurately in only four of nine eyes (44%).
CONCLUSIONS: The most common cause of vitreous hemorrhage was proliferative diabetic retinopathy, followed by ocular trauma. U/S correctly diagnosed all cases of retinal detachment, but less than 50% of retinal tears. A total of 18.9% of the eyes were falsely diagnosed as having retinal detachment. U/S is an effective diagnostic tool in patients with vitreous hemorrhage.

Entities:  

Mesh:

Year:  2004        PMID: 15004573     DOI: 10.1038/sj.eye.6700632

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  17 in total

1.  Efficacy of High Frequency Ultrasound in Localization and Characterization of Orbital Lesions.

Authors:  Rashmi M Nagaraju; G Gurushankar; Bindushree Kadakola
Journal:  J Clin Diagn Res       Date:  2015-09-01

2.  Early vitrectomy for fundus-obscuring dense vitreous haemorrhage from presumptive retinal tears.

Authors:  Narendra Dhingra; Ian Pearce; David Wong
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2007-02       Impact factor: 3.117

3.  VISUALIZATION FROM INTRAOPERATIVE SWEPT-SOURCE MICROSCOPE-INTEGRATED OPTICAL COHERENCE TOMOGRAPHY IN VITRECTOMY FOR COMPLICATIONS OF PROLIFERATIVE DIABETIC RETINOPATHY.

Authors:  Hesham Gabr; Xi Chen; Oscar M Zevallos-Carrasco; Christian Viehland; Alexandria Dandrige; Neeru Sarin; Tamer H Mahmoud; Lejla Vajzovic; Joseph A Izatt; Cynthia A Toth
Journal:  Retina       Date:  2018-09       Impact factor: 4.256

4.  The predictive value of echography in diabetic vitreous hemorrhage.

Authors:  M Selim Kocabora; Gokhan Gulkilik; Cemil Yilmazli; Muhittin Taskapili; Aysegul Kocabora
Journal:  Int Ophthalmol       Date:  2007-02-21       Impact factor: 2.031

Review 5.  Controversies in ocular trauma classification and management: review.

Authors:  Rupesh Agrawal; Mehul Shah; Kamiar Mireskandari; Goh Kong Yong
Journal:  Int Ophthalmol       Date:  2013-01-22       Impact factor: 2.031

6.  Predictive factors for final outcome of severely traumatized eyes with no light perception.

Authors:  Rupesh Agrawal; Ho Sue Wei; Stephen Teoh
Journal:  BMC Ophthalmol       Date:  2012-06-19       Impact factor: 2.209

7.  Imaging in Diabetic Retinopathy.

Authors:  Jasmin Zvorničanin; Edita Zvorničanin
Journal:  Middle East Afr J Ophthalmol       Date:  2015 Oct-Dec

8.  Accuracy of B-scan ultrasonography in acute fundus obscuring vitreous hemorrhage using a standardized scanning protocol and a dedicated ophthalmic ultrasonographer.

Authors:  Maria T Sandinha; Ajay K Kotagiri; Rona I Owen; Caspar Geenen; David Hw Steel
Journal:  Clin Ophthalmol       Date:  2017-07-27

9.  [Value of ultrasonography in eye injuries at Parakou (Benin)].

Authors:  Kofi-Mensa Savi de Tove; Abel Rodrigue Assavedo; Patricia Yekpe; Zakari Nikiema; Olivier Biaou; Vicentia Boco
Journal:  Pan Afr Med J       Date:  2013-07-28

10.  Diagnostic Accuracy of Ultrasound B scan using 10 MHz linear probe in ocular trauma;results from a high burden country.

Authors:  Muhammad Kashif Shazlee; Muhammad Ali; Muhammad SaadAhmed; Ammad Hussain; Kamran Hameed; Irfan Amjad Lutfi; Muhammad Tahir Khan
Journal:  Pak J Med Sci       Date:  2016 Mar-Apr       Impact factor: 1.088

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.