Literature DB >> 15000766

Clinical evaluation of a continuous minimally invasive glucose flux sensor placed over ultrasonically permeated skin.

Han Chuang1, Elizabeth Taylor, Thomas W Davison.   

Abstract

Frequent monitoring and tight metabolic control of blood glucose levels can reduce microvascular complications and subsequent co-morbidities in patients with diabetes. Self-monitoring with finger sticks provides intermittent data at best, and results in poor compliance. We report on a minimally invasive system that continually measures glucose flux through ultrasonically permeated skin. Ten patients with diabetes were enrolled in a clinical study to determine correlation between data collected by glucose biosensors placed over ultrasonically treated skin sites (two per patient), and blood glucose readings were taken every 20 min over an 8-h period. Glucose flux biosensors measured amperometric current proportional to hydrogen peroxide level, generated from catalytic conversion of glucose by glucose oxidase; the sensor was coupled to the skin by a thin hydrogel containing an osmotic extraction buffer, creating a gradient for glucose transport through the skin. The biosensors were attached to small portable meters that recorded time, current, and temperature readings every 5 s. At the conclusion of the study period, meter recordings were downloaded for data processing. Skin sites were examined for irritation due to biosensor contact. Data from glucose biosensors with completed data sets had a correlation coefficient of 0.84, and 95% of the data pairs (n = 241) were in the A + B region of a Clarke error grid. Ultrasonic pretreatment lasting about 10 s resulted in improved conductance in all patients. No patients complained of pain or irritation at any time during the study. Continuous monitoring of glucose flux through ultrasonically permeable skin is safe and feasible.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15000766     DOI: 10.1089/152091504322783378

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  12 in total

Review 1.  Delays in minimally invasive continuous glucose monitoring devices: a review of current technology.

Authors:  D Barry Keenan; John J Mastrototaro; Gayane Voskanyan; Garry M Steil
Journal:  J Diabetes Sci Technol       Date:  2009-09-01

2.  Sampling of disease biomarkers from skin for theranostic applications.

Authors:  Makoto Ogura; Sumit Paliwal; Samir Mitragotri
Journal:  Drug Deliv Transl Res       Date:  2012-04       Impact factor: 4.617

3.  Pilot studies of transdermal continuous glucose measurement in outpatient diabetic patients and in patients during and after cardiac surgery.

Authors:  Han Chuang; My-Quyen Trieu; James Hurley; Elizabeth J Taylor; Michael R England; Stanley A Nasraway
Journal:  J Diabetes Sci Technol       Date:  2008-07

4.  Fetal membrane transport enhancement using ultrasound for drug delivery and noninvasive detection.

Authors:  Lior Wolloch; Aharon Azagury; Riki Goldbart; Tamar Traitel; Gabriel Groisman; Mordechai Hallak; Joseph Kost
Journal:  Pharm Res       Date:  2014-07-31       Impact factor: 4.200

Review 5.  Ultrasound-mediated transdermal drug delivery: mechanisms, scope, and emerging trends.

Authors:  Baris E Polat; Douglas Hart; Robert Langer; Daniel Blankschtein
Journal:  J Control Release       Date:  2011-01-14       Impact factor: 9.776

6.  Cutaneous Complications With Continuous or Flash Glucose Monitoring Use: Systematic Review of Trials and Observational Studies.

Authors:  Nurul A Mohd Asarani; Andrew N Reynolds; Sara E Boucher; Martin de Bock; Benjamin J Wheeler
Journal:  J Diabetes Sci Technol       Date:  2019-08-27

7.  Interstitium versus Blood Equilibrium in Glucose Concentration and its Impact on Subcutaneous Continuous Glucose Monitoring Systems.

Authors:  Cosimo Scuffi
Journal:  Eur Endocrinol       Date:  2014-02-28

Review 8.  Low-frequency sonophoresis: application to the transdermal delivery of macromolecules and hydrophilic drugs.

Authors:  Baris E Polat; Daniel Blankschtein; Robert Langer
Journal:  Expert Opin Drug Deliv       Date:  2010-12       Impact factor: 6.648

Review 9.  Transdermal drug delivery.

Authors:  Mark R Prausnitz; Robert Langer
Journal:  Nat Biotechnol       Date:  2008-11       Impact factor: 54.908

10.  Design, development, and evaluation of a novel microneedle array-based continuous glucose monitor.

Authors:  Arvind Jina; Michael J Tierney; Janet A Tamada; Scott McGill; Shashi Desai; Beelee Chua; Anna Chang; Mark Christiansen
Journal:  J Diabetes Sci Technol       Date:  2014-03-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.