Literature DB >> 15000616

MicroCT scanner performance and considerations for vascular specimen imaging.

Michael Marxen1, Michael M Thornton, Cameron B Chiarot, Giannoula Klement, Janet Koprivnikar, John G Sled, R Mark Henkelman.   

Abstract

Obtaining three-dimensional geometrical data of vascular systems is of major importance to a number of research areas in medicine and biology. Examples are the characterization of tumor vasculature, modeling blood flow, or genetic effects on vascular development. The performance of the General Electric Medical Systems MS8 microCT scanner is examined in the context of these applications. The system is designed to acquire high-resolution images of specimens up to 5 cm in diameter. A maximum resolution of 38 lp/mm at the 10% modulation transfer function level or 22 microm full width at half maximum of the plane spread function can be achieved with 8.5 microm voxels and a 17 mm field of view. Three different contrast agents are discussed and applied for imaging of small animal vasculature: corrosion casting material Batson's No. 17 with an added lead pigment, silicon rubber MICROFIL MV122, and a suspension of barium sulfate (Baritop) in gelatin. Contrast for all of these agents was highly variable in different vessels as well as within the same vessel. Imaging of PMMA tubing filled with MICROFIL shows that even vessels below 20 microm in diameter are detectable and that diameter estimation of vessels based on thresholding is possible with a precision of 2-3 pixels.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15000616     DOI: 10.1118/1.1637971

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  42 in total

1.  Retrograde perfusion and filling of mouse coronary vasculature as preparation for micro computed tomography imaging.

Authors:  Jill J Weyers; Dara D Carlson; Charles E Murry; Stephen M Schwartz; William M Mahoney
Journal:  J Vis Exp       Date:  2012-02-10       Impact factor: 1.355

Review 2.  Anatomical and microstructural imaging of angiogenesis.

Authors:  Fabian Kiessling; Daniel Razansky; Frauke Alves
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-08       Impact factor: 9.236

3.  Algorithm-enabled low-dose micro-CT imaging.

Authors:  Xiao Han; Junguo Bian; Diane R Eaker; Timothy L Kline; Emil Y Sidky; Erik L Ritman; Xiaochuan Pan
Journal:  IEEE Trans Med Imaging       Date:  2010-10-25       Impact factor: 10.048

4.  Growth, ageing and scaling laws of coronary arterial trees.

Authors:  Xi Chen; Pei Niu; Xiaolong Niu; Wenzeng Shen; Fei Duan; Liang Ding; Xiliang Wei; Yanjun Gong; Yong Huo; Ghassan S Kassab; Wenchang Tan; Yunlong Huo
Journal:  J R Soc Interface       Date:  2015-12-06       Impact factor: 4.118

5.  Mineral volume and morphology in carotid plaque specimens using high-resolution MRI and CT.

Authors:  Ronald L Wolf; Suzanne L Wehrli; Andra M Popescu; John H Woo; Hee Kwon Song; Alexander C Wright; Emile R Mohler; John D Harding; Eric L Zager; Ronald M Fairman; Michael A Golden; Omaida C Velazquez; Jeffrey P Carpenter; Felix W Wehrli
Journal:  Arterioscler Thromb Vasc Biol       Date:  2005-06-09       Impact factor: 8.311

Review 6.  Small animal imaging facility: new perspectives for the radiologist.

Authors:  R Grassi; C Cavaliere; S Cozzolino; L Mansi; S Cirillo; G Tedeschi; R Franchi; P Russo; S Cornacchia; A Rotondo
Journal:  Radiol Med       Date:  2008-12-11       Impact factor: 3.469

7.  Spatiotemporal Analyses of Osteogenesis and Angiogenesis via Intravital Imaging in Cranial Bone Defect Repair.

Authors:  Chunlan Huang; Vincent P Ness; Xiaochuan Yang; Hongli Chen; Jiebo Luo; Edward B Brown; Xinping Zhang
Journal:  J Bone Miner Res       Date:  2015-07       Impact factor: 6.741

Review 8.  Anniversary paper. Development of x-ray computed tomography: the role of medical physics and AAPM from the 1970s to present.

Authors:  Xiaochuan Pan; Jeffrey Siewerdsen; Patrick J La Riviere; Willi A Kalender
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

9.  Feasibility and safety of silicone rubber contrast-enhanced microcomputed tomography in evaluating the angioarchitecture of prostatectomy specimens.

Authors:  Alex K Yeung; Mostafa Atri; Linda Sugar; Laurence Klotz
Journal:  Transl Oncol       Date:  2011-06-01       Impact factor: 4.243

10.  Micro-computed tomography for hemorrhage disruption of mouse brain vasculature.

Authors:  Bohua Xie; Peng Miao; Yuhao Sun; Yongting Wang; Guo-Yuan Yang
Journal:  Transl Stroke Res       Date:  2012-04-18       Impact factor: 6.829

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.