Literature DB >> 15000610

A technique for noninvasive respiratory gated radiation treatment system based on a real time 3D ultrasound image correlation: a phantom study.

Akira Sawada1, Kiyoshi Yoda, Masaki Kokubo, Tatsuya Kunieda, Yasushi Nagata, Masahiro Hiraoka.   

Abstract

This paper proposes a new respiratory gated radiation treatment system that allows real-time tumor localization while avoiding invasive operation to a patient. The proposed system employs a three-dimensional (3D) ultrasound device, a 3D digital localizer, and a real-time image processing system. At the planning time, CT and 3D ultrasound reference data are simultaneously acquired under a breath-hold condition. At the treatment time, ultrasound data on three orthogonal planes are acquired and transferred to the image processing system on a real-time basis. Subsequently, normalized image correlation indices using the reference and the real-time ultrasound data are calculated for the three orthogonal planes after performing real-time coordinate transform using the 3D digital localizer attached to an ultrasound probe. Prior to the system execution, the coordinate transform matrices are partially calculated using an ultrasound calibration phantom and the 3D digital localizer. A trigger pulse to a linac can be generated when the normalized image correlation index exceeds a predetermined threshold level. Experiments have been carried out using a moving-target phantom that simulates a patient respiratory motion. We have observed that the variation of the calculated real-time correlation index synchronizes with the periodical motion of the moving-target, suggesting that real-time localization for a moving tumor is feasible with the proposed system.

Entities:  

Mesh:

Year:  2004        PMID: 15000610     DOI: 10.1118/1.1634482

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  [Image-guided radiation therapy].

Authors:  J Boda-Heggemann; M Guckenberger; U Ganswindt; C Belka; H Wertz; M Blessing; F Wenz; M Fuss; F Lohr
Journal:  Radiologe       Date:  2012-03       Impact factor: 0.635

2.  Experimental verification of the utility of positron emitter nuclei generated by photonuclear reactions for X-ray beam monitoring in a phantom.

Authors:  Teiji Nishio; Taku Inaniwa; Kazumasa Inoue; Aya Miyatake; Keiichi Nakagawa; Kiyoshi Yoda; Takashi Ogino
Journal:  Radiat Med       Date:  2007-12-25

3.  System Integration and In Vivo Testing of a Robot for Ultrasound Guidance and Monitoring During Radiotherapy.

Authors:  Hasan Tutkun Sen; Muyinatu A Lediju Bell; Yin Zhang; Kai Ding; Emad Boctor; John Wong; Iulian Iordachita; Peter Kazanzides
Journal:  IEEE Trans Biomed Eng       Date:  2016-10-03       Impact factor: 4.538

4.  Development of a geometry-based respiratory motion-simulating patient model for radiation treatment dosimetry.

Authors:  Juying Zhang; George X Xu; Chengyu Shi; Martin Fuss
Journal:  J Appl Clin Med Phys       Date:  2008-01-21       Impact factor: 2.102