Literature DB >> 14999759

Apparent viscoelastic anisotropy as measured from nondestructive oscillatory tests can reflect the presence of a flaw in cortical bone.

Yener N Yeni1, Gregory T Christopherson, A Simon Turner, Clifford M Les, David P Fyhrie.   

Abstract

There is evidence that damage, viscoelastic stiffness properties, and postyield mechanical properties are related in bone tissue. Our objective was to test whether presence of a flaw would have an influence on the apparent viscoelastic properties of bone. Examining the effect of flaw orientation on apparent viscoelastic properties and utilization of dynamic mechanical analysis (DMA) as a nondestructive means for detection of damage were our secondary objectives. Cortical bone beams (2 x 2 x 19 mm) machined from the cranial cortex of the radii of six Warhill sheep were used. The specimens were placed in a DMA machine and baseline measurements of storage modulus (E1) and loss factor (tan delta), once for loads in the craniocaudal and once in the mediolateral directions, were performed using a three-point bending configuration for a frequency range of 1-10 Hz. Craniocaudal/mediolateral measurement ratio was calculated as a measure of anisotropy for tan delta and E1. After cutting a thin through-thickness macroscopic notch on the caudal surface at the center of each beam, oscillatory tests were repeated. Two-way repeated measures analysis of variance followed by Tukey's test was used with group (craniocaudal, mediolateral, notched craniocaudal, and notched mediolateral measurements) and frequency as factors. Regression analysis and analysis of covariance were used for examining the relationship between viscoelastic parameters and frequency. Tan delta and E1 were not different between craniocaudal and mediolateral measurements before the flaw was introduced (p > 0.8 and p = 1, respectively). In the presence of the flaw, tan delta was significantly increased (p < 0.003) whereas E1 was significantly reduced (p < 0.001) for craniocaudal measurements. Tan delta and E1 were nearly isotropic in the tested directions before the introduction of a flaw into the bone tissue. Introduction of a flaw resulted in increased tan delta and E1 anisotropy. Presence of a notch resulted in a significant increase in tan delta anisotropy with increasing frequency. In conclusion, we have demonstrated that cortical bone tissue exhibits a different apparent viscoelastic behavior in the presence of a flaw and depending on the flaw's orientation. Our finding that the presence of a notch and its orientation can be detected by nondestructive DMA suggests that in vivo techniques may be developed for detection of cortical bone damage. Copyright 2004 Wiley Periodicals, Inc. J Biomed Mater Res 69A: 124-130, 2004

Entities:  

Mesh:

Year:  2004        PMID: 14999759     DOI: 10.1002/jbm.a.20128

Source DB:  PubMed          Journal:  J Biomed Mater Res A        ISSN: 1549-3296            Impact factor:   4.396


  4 in total

1.  Constitutive relationship of tissue behavior with damage accumulation of human cortical bone.

Authors:  Qing Luo; Huijie Leng; Rae Acuna; Xuanliang Neil Dong; Qiguo Rong; Xiaodu Wang
Journal:  J Biomech       Date:  2010-05-15       Impact factor: 2.712

2.  Orientation dependence of progressive post-yield behavior of human cortical bone in compression.

Authors:  Xuanliang N Dong; Rae L Acuna; Qing Luo; Xiaodu Wang
Journal:  J Biomech       Date:  2012-09-17       Impact factor: 2.712

3.  Differences in the mechanical behavior of cortical bone between compression and tension when subjected to progressive loading.

Authors:  Jeffry S Nyman; Huijie Leng; X Neil Dong; Xiaodu Wang
Journal:  J Mech Behav Biomed Mater       Date:  2008-12-13

4.  Mechanical behavior of human cortical bone in cycles of advancing tensile strain for two age groups.

Authors:  Jeffry S Nyman; Anuradha Roy; Michael J Reyes; Xiaodu Wang
Journal:  J Biomed Mater Res A       Date:  2009-05       Impact factor: 4.396

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.