Literature DB >> 14996559

Investigation of fixation screw pull-out strength on human spine.

Q H Zhang1, S H Tan, S M Chou.   

Abstract

For the purpose of fixation and stabilizing the spine, the pull-out strength of the screw is one of the most important factors to be considered. The material properties of the bone, coupled with the principal dimensions of the screw such as major diameter, minor diameter, pitch and purchase length, may affect the pull-out strength of the fixation screw. In this study, the effects of various factors on the bone screw pull-out strength were studied using finite element method of analysis. A three-dimensional finite element model simulating the threaded connection of bone and surgical screw was constructed. The behavior of both the bone and the screw during screw pull-out were analyzed and discussed. The effect of the screw parameters on the screw pull-out strength was also investigated. The results showed that failure of the connection was due to bone shearing which occurred along a cylindrical surface determined by the outer perimeter of the screw and penetrated length. The distribution of the shear stress along the threaded length in the bone was nearly uniform. The effect of the major diameter on the screw pull-out strength was more significant than those of the minor diameter and the pitch. The minor diameter hardly affected the pull-out strength.

Entities:  

Mesh:

Year:  2004        PMID: 14996559     DOI: 10.1016/j.jbiomech.2003.09.005

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  14 in total

1.  Cervical anterior transpedicular screw fixation (ATPS)--Part II. Accuracy of manual insertion and pull-out strength of ATPS.

Authors:  Heiko Koller; Frank Acosta; Mark Tauber; Michael Fox; Hudelmaier Martin; Rosmarie Forstner; Peter Augat; Rainer Penzkofer; Christian Pirich; H Kässmann; Herbert Resch; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2008-01-26       Impact factor: 3.134

2.  Quantitative dual-energy CT for phantomless evaluation of cancellous bone mineral density of the vertebral pedicle: correlation with pedicle screw pull-out strength.

Authors:  Julian L Wichmann; Christian Booz; Stefan Wesarg; Ralf W Bauer; J Matthias Kerl; Sebastian Fischer; Thomas Lehnert; Thomas J Vogl; M Fawad Khan; Konstantinos Kafchitsas
Journal:  Eur Radiol       Date:  2014-12-07       Impact factor: 5.315

3.  Analysis of stress induced by screws in the vertebral fixation system.

Authors:  Sarah Fakher Fakhouri; Marcos Massao Shimano; Cleudmar Amaral de Araújo; Helton Luiz Aparecido Defino; Antônio Carlos Shimano
Journal:  Acta Ortop Bras       Date:  2014       Impact factor: 0.513

4.  Does addition of crosslink to pedicle-screw-based instrumentation impact the development of the spinal canal in children younger than 5 years of age?

Authors:  Zhong-hui Chen; Xi Chen; Ze-zhang Zhu; Bin Wang; Bang-ping Qian; Feng Zhu; Xu Sun; Yong Qiu
Journal:  Eur Spine J       Date:  2014-12-20       Impact factor: 3.134

5.  Simulation of an anterior spine instrumentation in adolescent idiopathic scoliosis using a flexible multi-body model.

Authors:  Geneviève Desroches; Carl-Eric Aubin; Daniel J Sucato; Charles-Hilaire Rivard
Journal:  Med Biol Eng Comput       Date:  2007-07-12       Impact factor: 2.602

6.  Comparison of Partially Threaded and Fully Threaded 4mm Cancellous Screws in Fixation of Medial Malleolar Fractures.

Authors:  Sayyed-Hadi Sayyed-Hosseinian; Farshid Bagheri; Mohammad-Hosien Ebrahimzadeh; Ali Moradi; Sogol Golshan
Journal:  Arch Bone Jt Surg       Date:  2020-11

7.  Pullout strength of misplaced pedicle screws in the thoracic and lumbar vertebrae - A cadaveric study.

Authors:  Shyam K Saraf; Ravindra P Singh; Vakil Singh; Ashish Varma
Journal:  Indian J Orthop       Date:  2013-05       Impact factor: 1.251

8.  Effect of bone material properties on effective region in screw-bone model: an experimental and finite element study.

Authors:  Shuai Liu; Wei Qi; Yang Zhang; Zi-Xiang Wu; Ya-Bo Yan; Wei Lei
Journal:  Biomed Eng Online       Date:  2014-06-21       Impact factor: 2.819

9.  Pullout of a lumbar plate with varying screw lengths.

Authors:  Daniel Kyle Palmer; David Rios; Wyzscx Merfil Patacxil; Paul A Williams; Wayne K Cheng; Serkan İnceoğlu
Journal:  Int J Spine Surg       Date:  2012-12-01

10.  Parametric analysis of orthopedic screws in relation to bone density.

Authors:  Elisabetta M Zanetti; Massimiliano Salaorno; Giovanni Grasso; Alberto L Audenino
Journal:  Open Med Inform J       Date:  2009-04-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.