Literature DB >> 14994890

A comparative study of the static and kinetic frictional resistance of titanium molybdenum alloy archwires in stainless steel brackets.

A Cash1, R Curtis, D Garrigia-Majo, F McDonald.   

Abstract

This ex vivo study compared the static and kinetic frictional resistance of eight different archwires tested in a single, stainless steel, zero base 0.022 x 0.028 inch (0.56 x 0.711 mm) slot standard edgewise bracket. The archwires evaluated were 0.019 x 0.025 inch (0.483 x 0.636 mm) in dimension, manufactured from the following alloys: beta titanium (TMA), 'low friction' coloured beta titanium (aqua, honeydew, purple and violet), ion-implanted beta titanium, Timolium and a stainless steel control. Prior to friction testing, bracket and archwire dimensions were measured by direct digital imaging via a desktop computer linked to a binocular light microscope. Frictional force was evaluated using an Instron universal testing machine. All experiments were carried out at room temperature, with no ligation, in the dry state with 20 degrees of added torque. The results demonstrated that static and kinetic friction were statistically significant (P < 0.001) for all archwire types. Ion-implanted and standard TMA archwires were found to have no significant advantage over stainless steel. The archwire alloys may be ranked as follows: stainless steel produced the lowest frictional resistance followed by honeydew, ion-implanted TMA and Timolium, with aqua, purple and violet producing frictional resistance values as high as standard TMA. It was also found that the percentage difference between the archwire and bracket slot dimensions claimed by the manufacturers and those measured in this experiment produced tolerances ranging from +5.37 to -6.67 per cent.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14994890     DOI: 10.1093/ejo/26.1.105

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  13 in total

1.  Comparative Evaluation of Frictional Properties, Load Deflection Rate and Surface Characteristics of Different Coloured TMA Archwires - An Invitro Study.

Authors:  Arul Pradeep Aloysius; Devaki Vijayalakshmi; Nagachandran Kandasamy Soundararajan; Vijaykumar Neelam Manohar; Nayeemullah Khan
Journal:  J Clin Diagn Res       Date:  2015-12-01

2.  [Comparison of friction force between Lock-loose bracket and traditional bracket].

Authors:  Liu Xiaowei; Yang Luyi; Zhu Huifang; Dong Yan; Wang Qi; Jiang Wei; Wu Yanran
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2014-12

3.  Effect of anodization on friction behavior of β‑titanium orthodontic archwires.

Authors:  Yueh-Tse Lee; Eric Jein-Wein Liou; Li-Ling Huang; Hsin-Jay Wu; Sinn-Wen Chen
Journal:  J Orofac Orthop       Date:  2021-09-17       Impact factor: 1.938

4.  Comparison of surface topography of low-friction and conventional TMA orthodontic arch wires using atomic force microscopy.

Authors:  Nouf I Alsabti; Christoph P Bourauel; Nabeel F Talic
Journal:  J Orthod Sci       Date:  2021-02-19

5.  Friction between different wire bracket combinations in artificial saliva--an in vitro evaluation.

Authors:  Tatiana Kelly da Silva Fidalgo; Matheus Melo Pithon; José Vinicius Bolognesi Maciel; Ana Maria Bolognese
Journal:  J Appl Oral Sci       Date:  2011 Jan-Feb       Impact factor: 2.698

6.  Static and kinetic frictional forces of silica-insert ceramic brackets with coated archwires in artificial saliva.

Authors:  Mostafa Shahabi; Soheil Salari; Maryam Poosti; Mostafa Abtahi
Journal:  Dent Res J (Isfahan)       Date:  2017 Nov-Dec

7.  Effect of dry heat and steam sterilization on load-deflection characteristics of β-titanium wires: An in vitro study.

Authors:  Shiva Alavi; Neda Sinaee
Journal:  Dent Res J (Isfahan)       Date:  2012-09

8.  The effect of zinc oxide nanoparticles deposition for friction reduction on orthodontic wires.

Authors:  Mojghan Kachoei; Faranak Eskandarinejad; Baharak Divband; Masumeh Khatamian
Journal:  Dent Res J (Isfahan)       Date:  2013-07

9.  In Vitro Comparative Evaluation of Frictional Resistance of Connecticut New Arch Wires, Stainless Steel and Titanium Molybdenum Alloy Archwires Against Different Brackets.

Authors:  Shraddha Suryavanshi; Uma Lingareddy; Nausheer Ahmed; Kiran Kumar Neelakantappa; Nishat Sidiqha; Manisha Minz
Journal:  Cureus       Date:  2019-11-12

10.  Comparison of force loss during sliding of low friction and conventional TMA orthodontic archwires : An in vitro study.

Authors:  Nouf Alsabti; Christoph Bourauel; Nabeel Talic
Journal:  J Orofac Orthop       Date:  2020-12-02       Impact factor: 1.938

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.