Literature DB >> 14993127

Clinical, angiographic, and procedural predictors of angiographic restenosis after sirolimus-eluting stent implantation in complex patients: an evaluation from the Rapamycin-Eluting Stent Evaluated At Rotterdam Cardiology Hospital (RESEARCH) study.

Pedro A Lemos1, Angela Hoye, Dick Goedhart, Chourmouzios A Arampatzis, Francesco Saia, Willem J van der Giessen, Eugene McFadden, Georgios Sianos, Pieter C Smits, Sjoerd H Hofma, Pim J de Feyter, Ron T van Domburg, Patrick W Serruys.   

Abstract

BACKGROUND: The factors associated with the occurrence of restenosis after sirolimus-eluting stent (SES) implantation in complex cases are currently unknown. METHODS AND
RESULTS: A cohort of consecutive complex patients treated with SES implantation was selected according to the following criteria: (1) treatment of acute myocardial infarction, (2) treatment of in-stent restenosis, (3) 2.25-mm diameter SES, (4) left main coronary stenting, (5) chronic total occlusion, (6) stented segment >36 mm, and (7) bifurcation stenting. The present study population was composed of 238 patients (441 lesions) for whom 6-month angiographic follow-up data were obtained (70% of eligible patients). Significant clinical, angiographic, and procedural predictors of post-SES restenosis were evaluated. Binary in-segment restenosis was diagnosed in 7.9% of lesions (6.3% in-stent, 0.9% at the proximal edge, 0.7% at the distal edge). The following characteristics were identified as independent multivariate predictors: treatment of in-stent restenosis (OR 4.16, 95% CI 1.63 to 11.01; P<0.01), ostial location (OR 4.84, 95% CI 1.81 to 12.07; P<0.01), diabetes (OR 2.63, 95% CI 1.14 to 6.31; P=0.02), total stented length (per 10-mm increase; OR 1.42, 95% CI 1.21 to 1.68; P<0.01), reference diameter (per 1.0-mm increase; OR 0.46, 95% CI 0.24 to 0.87; P=0.03), and left anterior descending artery (OR 0.30, 95% CI 0.10 to 0.69; P<0.01).
CONCLUSIONS: Angiographic restenosis after SES implantation in complex patients is an infrequent event, occurring mainly in association with lesion-based characteristics and diabetes mellitus.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14993127     DOI: 10.1161/01.CIR.0000121358.26097.06

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  39 in total

1.  Surface grafting of blood compatible zwitterionic poly(ethylene glycol) on diamond-like carbon-coated stent.

Authors:  Bong Soo Lee; Hong-Sub Shin; Kwideok Park; Dong Keun Han
Journal:  J Mater Sci Mater Med       Date:  2011-01-30       Impact factor: 3.896

Review 2.  Surgery is the best intervention for severe coronary artery disease.

Authors:  David P Taggart
Journal:  BMJ       Date:  2005-04-02

3.  Angiographic segment size in patients referred for coronary intervention is influenced by constitutional, anatomical, and clinical features.

Authors:  Pedro A Lemos; Expedito E Ribeiro; Marco A Perin; Luiz J Kajita; Marco A de Magalhães; João L A A Falcão; Antonio Esteves Filho; Marcus N da Gama; Pedro E Horta; Gilberto G Marchiori; Andre G Spadaro; Eulógio E Martinez
Journal:  Int J Cardiovasc Imaging       Date:  2006-06-30       Impact factor: 2.357

Review 4.  Stents or surgery: the case for stents.

Authors:  James M Wilson
Journal:  Tex Heart Inst J       Date:  2005

5.  Incidence and predictors of target vessel revascularization after sirolimus-eluting stent treatment for proximal left anterior descending artery stenoses among 2274 patients from the prospective multicenter German Cypher Stent Registry.

Authors:  Ahmed A Khattab; Christian W Hamm; Jochen Senges; Ralph Toelg; Volker Geist; Tassilo Bonzel; Malte Kelm; Benny Levenson; Christoph A Nienaber; Georg Sabin; Ulrich Tebbe; Steffen Schneider; Gert Richardt
Journal:  Clin Res Cardiol       Date:  2007-02-26       Impact factor: 5.460

6.  The prevention and treatment of restenosis in the era of drug-eluting stent.

Authors:  Min-zhou Zhang
Journal:  Chin J Integr Med       Date:  2007-03       Impact factor: 1.978

7.  Three-dimensional coronary imaging for the ostium of the left anterior descending artery.

Authors:  Kenji Sadamatsu; Shuichiro Sagara; Tohru Yamawaki; Hideki Tashiro
Journal:  Int J Cardiovasc Imaging       Date:  2008-11-26       Impact factor: 2.357

8.  Scanning electron microscopic analysis of polymer damage in drug-eluting stents during multiple stenting.

Authors:  Aiko Shimokado; Takashi Kubo; Hirotoshi Utsunomiya; Hisashi Yamasaki; Takashi Tanimoto; Yasushi Ino; Yong Liu; Ikuko Teraguchi; Yuichi Ozaki; Yasutsugu Shiono; Makoto Orii; Kunihiro Shimamura; Takashi Yamano; Tomoyuki Yamaguchi; Kumiko Hirata; Toshio Imanishi; Takashi Akasaka
Journal:  Int J Cardiovasc Imaging       Date:  2013-09-13       Impact factor: 2.357

9.  Sirolimus-eluting stent treatment for isolated proximal left anterior descending artery stenoses. Results from the prospective multi-center German Cypher Registry.

Authors:  A A Khattab; C W Hamm; J Senges; R Toelg; V Geist; T Bonzel; M Kelm; B Levenson; C A Nienaber; G Sabin; S Schneider; U Tebbe; G Richardt
Journal:  Z Kardiol       Date:  2005-03

10.  Complex coronary lesions and rotational atherectomy: one hospital's experience.

Authors:  Jun Jiang; Yong Sun; Mei-xiang Xiang; Liang Dong; Xian-bao Liu; Xin-yang Hu; Yan Feng; Jian-an Wang
Journal:  J Zhejiang Univ Sci B       Date:  2012-08       Impact factor: 3.066

View more