Literature DB >> 14991246

Improving the quality of small animal brain pinhole SPECT imaging by Bayesian reconstruction.

Antti Sohlberg1, Sanna Lensu, Jukka Jolkkonen, Leena Tuomisto, Ulla Ruotsalainen, Jyrki T Kuikka.   

Abstract

The possibility of using existing hardware makes pinhole single-photon emission computed tomography (SPECT) attractive when pursuing the ultra-high resolution required for small animal brain imaging. Unfortunately, the poor sensitivity and the heavy weight of the collimator hamper the use of pinhole SPECT in animal studies by generating noisy and misaligned projections. To improve the image quality we have developed a new Bayesian reconstruction method, pinhole median root prior (PH-MRP), which prevents the excessive noise accumulation from the projections to the reconstructed image. The PH-MRP algorithm was used to reconstruct data acquired with our small animal rotating device, which was designed to reduce the rotation orbit misalignments. Phantom experiments were performed to test the device and compare the PH-MRP with the conventional Feldkamp-Davis-Kress (FDK) and pinhole ordered subsets maximum likelihood expectation maximisation (PH-OSEM) reconstruction algorithms. The feasibility of the system for small animal brain imaging was studied with Han-Wistar rats injected with (123)I-epidepride and (99m)Tc-hydroxy methylene diphosphonate. Considering all the experiments, no shape distortions due to orbit misalignments were encountered and remarkable improvements in noise characteristics and also in overall image quality were observed when the PH-MRP was applied instead of the FDK or PH-OSEM. In addition, the proposed methods utilise existing hardware and require only a certain amount of construction and programming work, making them easy to implement.

Entities:  

Mesh:

Year:  2004        PMID: 14991246     DOI: 10.1007/s00259-004-1488-y

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  17 in total

1.  Interest of the ordered subsets expectation maximization (OS-EM) algorithm in pinhole single-photon emission tomography reconstruction: a phantom study.

Authors:  C Vanhove; M Defrise; P R Franken; H Everaert; F Deconinck; A Bossuyt
Journal:  Eur J Nucl Med       Date:  2000-02

Review 2.  Molecular imaging of small animals with dedicated PET tomographs.

Authors:  Arion F Chatziioannou
Journal:  Eur J Nucl Med Mol Imaging       Date:  2001-11-22       Impact factor: 9.236

Review 3.  Nuclear medicine applications in molecular imaging.

Authors:  Francis G Blankenberg; H William Strauss
Journal:  J Magn Reson Imaging       Date:  2002-10       Impact factor: 4.813

4.  Pinhole single-photon emission tomography reconstruction based on median root prior.

Authors:  Antti Sohlberg; Jyrki T Kuikka; Ulla Ruotsalainen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2002-11-08       Impact factor: 9.236

Review 5.  Contributions of PET and SPECT to the understanding of the pathophysiology of Parkinson's disease.

Authors:  S Thobois; S Guillouet; E Broussolle
Journal:  Neurophysiol Clin       Date:  2001-10       Impact factor: 3.734

6.  Evaluation of high-resolution pinhole SPECT using a small rotating animal.

Authors:  J B Habraken; K de Bruin; M Shehata; J Booij; R Bennink; B L van Eck Smit; E Busemann Sokole
Journal:  J Nucl Med       Date:  2001-12       Impact factor: 10.057

7.  Improved SPECT quantification using compensation for scattered photons.

Authors:  R J Jaszczak; K L Greer; C E Floyd; C C Harris; R E Coleman
Journal:  J Nucl Med       Date:  1984-08       Impact factor: 10.057

8.  Quantitative analysis of acute myocardial infarct in rat hearts with ischemia-reperfusion using a high-resolution stationary SPECT system.

Authors:  Zhonglin Liu; George A Kastis; Gail D Stevenson; Harrison H Barrett; Lars R Furenlid; Matthew A Kupinski; Dennis D Patton; Donald W Wilson
Journal:  J Nucl Med       Date:  2002-07       Impact factor: 10.057

9.  Performance evaluation of a pinhole SPECT system for myocardial perfusion imaging of mice.

Authors:  Max C Wu; Bruce H Hasegawa; Michael W Dae
Journal:  Med Phys       Date:  2002-12       Impact factor: 4.071

Review 10.  Neuroreceptor imaging in psychiatric disorders.

Authors:  W Gordon Frankle; Marc Laruelle
Journal:  Ann Nucl Med       Date:  2002-11       Impact factor: 2.668

View more
  2 in total

1.  Improved quantification in multiple-pinhole SPECT by anatomy-based reconstruction using microCT information.

Authors:  Christian Vanhove; Michel Defrise; Axel Bossuyt; Tony Lahoutte
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-09-30       Impact factor: 9.236

2.  No-carrier-added versus carrier-added123I-metaiodobenzylguanidine for the assessment of cardiac sympathetic nerve activity.

Authors:  Hein J Verberne; Kora de Bruin; Jan B A Habraken; G Aernout Somsen; Jos L H Eersels; Frits Moet; Jan Booij; Berthe L F van Eck-Smit
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-01-20       Impact factor: 9.236

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.