Literature DB >> 14987602

Implementing solenoid microcoils for wide-line solid-state NMR.

K Yamauchi1, J W G Janssen, A P M Kentgens.   

Abstract

Solid-state nuclear magnetic resonance (NMR) probeheads using solenoid microcoils with an inner diameter of 300-400 microm are developed for the study of mass-limited solid samples. Some attention is paid to the mechanical ruggedness of the probes allowing sample changing. The performance, in terms of sensitivity and RF-characteristics, of these probeheads is studied for (1)H, (31)P, and (27)Al in different model compounds in view of the feasibility of specific applications. The results show that the sensitivity is high enough to detect approximately 10(14) spins/sqrt Hz with a signal-to-noise ratio of 1 in a single scan. A specific advantage of microcoils for solid-state NMR applications is that they can generate extremely high RF-fields if implemented in appropriate circuits. Using RF-powers in the hundreds of Watts range, RF-fields well in excess of 1MHz can be made. This allows the excitation of spectra of nuclei whose resonance lines are dispersed of several megahertz. This is particularly useful for quadrupolar nuclei experiencing large quadrupolar interactions as is demonstrated for (27)Al in single crystal and powdered minerals.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14987602     DOI: 10.1016/j.jmr.2003.12.003

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  5 in total

1.  Microfabricated inserts for magic angle coil spinning (MACS) wireless NMR spectroscopy.

Authors:  Vlad Badilita; Birgit Fassbender; Kai Kratt; Alan Wong; Christian Bonhomme; Dimitris Sakellariou; Jan G Korvink; Ulrike Wallrabe
Journal:  PLoS One       Date:  2012-08-20       Impact factor: 3.240

2.  Ultrasensitive mechanical detection of magnetic moment using a commercial disk drive write head.

Authors:  Y Tao; A Eichler; T Holzherr; C L Degen
Journal:  Nat Commun       Date:  2016-09-20       Impact factor: 14.919

3.  Magnetic flux tailoring through Lenz lenses for ultrasmall samples: A new pathway to high-pressure nuclear magnetic resonance.

Authors:  Thomas Meier; Nan Wang; Dario Mager; Jan G Korvink; Sylvain Petitgirard; Leonid Dubrovinsky
Journal:  Sci Adv       Date:  2017-12-08       Impact factor: 14.136

4.  3D printed microchannels for sub-nL NMR spectroscopy.

Authors:  E Montinaro; M Grisi; M C Letizia; L Pethö; M A M Gijs; R Guidetti; J Michler; J Brugger; G Boero
Journal:  PLoS One       Date:  2018-05-09       Impact factor: 3.240

5.  Increasing the detection distance of remote NMR using wireless inductive coupling coil.

Authors:  Mario Henrique M Killner; Giancarlo Tosin; André S Carvalho; Diego Firme Bernardes; Luiz Alberto Colnago
Journal:  Sci Rep       Date:  2017-10-04       Impact factor: 4.379

  5 in total