A monolithic silicon optoelectronic transducer as a real-time affinity biosensor.

Konstantinos Misiakos1, Sotirios E Kakabakos, Panagiota S Petrou, Hans H Ruf.   

Abstract

An optical real-time affinity biosensor, which is based on a monolithic silicon optoelectronic transducer and a microfluidic module, is described. The transducer monolithically integrates silicon avalanche diodes as light sources, silicon nitride optical fibers, and p/n junction detectors and efficiently intercouples these elements through a self-alignment technique. The transducer surface is hydrophilized by oxygen plasma treatment, silanized with (3-aminopropyl)triethoxysilane and bioactivated through adsorption of the biomolecular probes. The use of a microfluidic module allows real-time monitoring of the binding reaction of the gold nanoparticle-labeled analytes with the immobilized probes. Their binding within the evanescent field at the surface of the optical fiber causes attenuated total reflection of the waveguided modes and reduction of the detector photocurrent. The biotin-streptavidin model assay was used for the evaluation of the analytical potentials of the device developed. Detection limits of 3.8 and 13 pM in terms of gold nanoparticle-labeled streptavidin were achieved for continuous- and stopped-flow assay modes, respectively. The detection sensitivity was improved by silver plating of the immobilized gold nanoparticles, and a detection limit of 20 fM was obtained after 20-min of silver plating. In addition, two different analytes, streptavidin and anti-mouse IgG, were simultaneously assayed on the same chip demonstrating the multianalyte potential of the sensor developed.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14987094     DOI: 10.1021/ac0353334

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  Internally calibrated quantification of protein analytes in human serum by fluorescence immunoassays in disposable elastomeric microfluidic devices.

Authors:  Emil P Kartalov; David H Lin; David T Lee; William F Anderson; Clive R Taylor; Axel Scherer
Journal:  Electrophoresis       Date:  2008-12       Impact factor: 3.535

2.  Internally calibrated quantification of VEGF in human plasma by fluorescence immunoassays in disposable elastomeric microfluidic devices.

Authors:  David H Lin; Clive R Taylor; W French Anderson; Axel Scherer; Emil P Kartalov
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2009-08-29       Impact factor: 3.205

3.  Mycotoxin Biosensor Based on Optical Planar Waveguide.

Authors:  Ali Al-Jawdah; Alexei Nabok; Radhyah Jarrah; Alan Holloway; Anna Tsargorodska; Eszter Takacs; Andras Szekacs
Journal:  Toxins (Basel)       Date:  2018-07-03       Impact factor: 4.546

4.  Highly sensitive label-free in vitro detection of aflatoxin B1 in an aptamer assay using optical planar waveguide operating as a polarization interferometer.

Authors:  Ali Al-Jawdah; Alexei Nabok; Hisham Abu-Ali; Gaelle Catanante; Jean-Louis Marty; Andras Szekacs
Journal:  Anal Bioanal Chem       Date:  2019-08-07       Impact factor: 4.142

5.  Monolithically integrated broad-band Mach-Zehnder interferometers for highly sensitive label-free detection of biomolecules through dual polarization optics.

Authors:  A Psarouli; A Salapatas; A Botsialas; P S Petrou; I Raptis; E Makarona; G Jobst; K Tukkiniemi; M Sopanen; R Stoffer; S E Kakabakos; K Misiakos
Journal:  Sci Rep       Date:  2015-12-02       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.