Literature DB >> 14987082

Detection of human immunoglobulin in microchip and conventional capillary electrophoresis with contactless conductivity measurements.

Eva M Abad-Villar1, Jatisai Tanyanyiwa, M Teresa Fernández-Abedul, Agustín Costa-García, Peter C Hauser.   

Abstract

The detection of human immunoglobulin M (IgM) was performed using capacitively coupled contactless conductivity detection (CCD) in electrophoresis carried out in conventional capillaries as well as on glass and poly(meth-yl methacrylate) (PMMA) microdevices. Also achieved was the analyses of IgG (an anti-human IgM) and the complex formed in the reaction between the two immunoreagents. It is demonstrated that CCD is a powerful tool suitable not only for the detection of antibodies but also for monitoring an immunological interaction. Conductivity measurements allow the direct determination of immunoreagents, and it is advantageous, since no labels are required. The immunoglobulin IgM has been taken as model analyte. The reproducibility of the analytical signal (RSD = 1%), sensitivity and limits of detection obtained for IgM (0.15 ng/mL in conventional capillaries and 34 ng/mL in microchips) are comparable to those previously obtained with amperometric detection. The immunological reaction was performed either in conventional microtiter plates as used in ELISA or in situ on the glass chip.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14987082     DOI: 10.1021/ac0346656

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

Review 1.  Recent applications of affinity interactions in capillary electrophoresis.

Authors:  Christian Schou; Niels H H Heegaard
Journal:  Electrophoresis       Date:  2006-01       Impact factor: 3.535

Review 2.  Clinical analysis by microchip capillary electrophoresis.

Authors:  Sam F Y Li; Larry J Kricka
Journal:  Clin Chem       Date:  2005-11-18       Impact factor: 8.327

3.  A plug-in electrophoresis microchip with PCB electrodes for contactless conductivity detection.

Authors:  Mingpeng Yang; Zhe Huang; Hui You
Journal:  R Soc Open Sci       Date:  2018-05-09       Impact factor: 2.963

4.  MCE-electrochemical detection for following interactions of ssDNA and dsDNA with methylene blue.

Authors:  Mario Castaño-Alvarez; Ana Fernández-la-Villa; María Teresa Fernández-Abedul; Agustín Costa-García
Journal:  Electrophoresis       Date:  2009-06       Impact factor: 3.535

5.  Electroactive intercalators for DNA analysis on microchip electrophoresis.

Authors:  Mario Castaño-Alvarez; M Teresa Fernández-Abedul; Agustín Costa-García
Journal:  Electrophoresis       Date:  2007-12       Impact factor: 3.535

  5 in total