Literature DB >> 1498446

Model of the dynamics of receptor potential in a mechanoreceptor.

J Bell1, M Holmes.   

Abstract

Mechanoreceptors are physiological units that convert mechanical stimuli to neural responses. An important one in the skin is the Pacinian corpuscle, which consists of a nerve ending surrounded by a capsule that is made up of alternating layers of fluid and elastic shells. In this paper a capsule model is coupled to a model for the dendrite via a variable representing the hoop strain imposed by the capsule on the receptor membrane of the dendrite. The transient behavior of the receptor potential due to step and periodic displacement-type stimuli imposed on the outer membrane of the capsule is investigated, and the results are compared to those of analogous experiments. The model is used to develop hypotheses concerning the role of the capsule as a filter for mechanical stimuli.

Mesh:

Year:  1992        PMID: 1498446     DOI: 10.1016/0025-5564(92)90034-t

Source DB:  PubMed          Journal:  Math Biosci        ISSN: 0025-5564            Impact factor:   2.144


  8 in total

1.  Tristate markov model for the firing statistics of rapidly-adapting mechanoreceptive fibers.

Authors:  Burak Güçlü; Stanley J Bolanowski
Journal:  J Comput Neurosci       Date:  2004 Sep-Oct       Impact factor: 1.621

2.  Empirically inspired simulated electro-mechanical model of the rat mystacial follicle-sinus complex.

Authors:  Ben Mitchinson; Kevin N Gurney; Peter Redgrave; Chris Melhuish; Anthony G Pipe; Martin Pearson; Ian Gilhespy; Tony J Prescott
Journal:  Proc Biol Sci       Date:  2004-12-07       Impact factor: 5.349

3.  A note on modeling mechano-chemical transduction with an application to a skin receptor.

Authors:  J Bell; M H Holmes
Journal:  J Math Biol       Date:  1994       Impact factor: 2.259

Review 4.  Fascial components of the myofascial pain syndrome.

Authors:  Antonio Stecco; Marco Gesi; Carla Stecco; Robert Stern
Journal:  Curr Pain Headache Rep       Date:  2013-08

5.  Comparative ultrasonographic evaluation of the Achilles paratenon in symptomatic and asymptomatic subjects: an imaging study.

Authors:  A Stecco; F Busoni; C Stecco; M Mattioli-Belmonte; P Soldani; S Condino; A Ermolao; M Zaccaria; M Gesi
Journal:  Surg Radiol Anat       Date:  2014-07-22       Impact factor: 1.246

Review 6.  Upper Limb Motor Impairment After Stroke.

Authors:  Preeti Raghavan
Journal:  Phys Med Rehabil Clin N Am       Date:  2015-08-25       Impact factor: 1.784

7.  Ultrasonography in myofascial neck pain: randomized clinical trial for diagnosis and follow-up.

Authors:  Antonio Stecco; Andrea Meneghini; Robert Stern; Carla Stecco; Marta Imamura
Journal:  Surg Radiol Anat       Date:  2013-08-23       Impact factor: 1.246

Review 8.  Viscoelastic Properties of Hyaluronan in Physiological Conditions.

Authors:  Mary K Cowman; Tannin A Schmidt; Preeti Raghavan; Antonio Stecco
Journal:  F1000Res       Date:  2015-08-25
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.