Literature DB >> 14982359

Bone scintigraphy and SPECT in the evaluation of the osseointegrative response to immediate prosthetic loading of endosseous implants: a pilot study.

Fabrizio Bambini1, Lucìa Memè, Maurizio Procaccini, Brunella Rossi, Lorenzo Lo Muzio.   

Abstract

PURPOSE: Several recent medical reports have focused attention on the possible application of skeletal scintigraphy imaging in odontostomatology. The aim of the present report was to assess the influence of immediate prosthetic loading on peri-implant osteoblastic activity through bone scintigraphy.
MATERIALS AND METHODS: Implants were placed in 2 healthy women. A nuclear medicine investigation with single-photon emission-computed tomography (SPECT) was performed for both patients at 30 and 90 days after implant placement. The study was completed with acquisitions of planar images of the skull in an anterior view and the use of regions of interest (ROIs) of the same size in the area corresponding to immediate loading and in the opposite hemimandible (at the control sites). Count density ratios (counts/pixel) obtained from each ROI were used for a quantitative/relative assessment. Tomographic images were evaluated with a qualitative method. The spatial resolution of the reconstructed tomograms and of the planar images was approximately 7 mm.
RESULTS: Routine planar methodology provided a direct measure of cellular activity of the examined areas. The difference in count density ratio registered from the same ROI between the first and the second scintigraphy revealed the course of peri-implant osteoblastic activity, which was very high in the first month and then declined during subsequent months. DISCUSSION AND
CONCLUSION: In spite of the small number of involved patients, the results obtained from this pilot study suggest that nuclear medicine may hold possible advantages in implant dentistry for those who seek to clarify the still unknown aspects of osteoblastic activity.

Entities:  

Mesh:

Year:  2004        PMID: 14982359

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  2 in total

1.  Na18F accumulates on the compressive side of peri-implant bone under immediate loading.

Authors:  Miou Yamamoto; Toru Ogawa; Masayoshi Yokoyama; Yoshihito Funaki; Kenta Shobara; Aya Shibamoto; Juan Ramón Vanegas Sáenz; Keiichi Sasaki
Journal:  Odontology       Date:  2017-12-13       Impact factor: 2.634

2.  Evaluation of osteoblastic activity in extraction sockets treated with platelet-rich fibrin.

Authors:  Ozgur Baslarli; Celal Tumer; Omer Ugur; Betul Vatankulu
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2015-01-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.