Abstract Background: Since 1994 at the authors' institution, approximately 9000 cardiac surgical procedures were performed using activated clotting time (ACT)-monitored heparin anticoagulation for cardiopulmonary bypass and protamine administration calculated from a standard unchanged formula. This formula incorporates physiologic consequences of bypass pump-induced dilutional coagulopathy, platelet dysfunction, and coagulation/fibrinolytic cascade component activation, and thus may overcorrect in a subset of off-pump coronary artery bypass graft (OPCAB) patients who may in fact manifest a relative perioperative hypercoagulability state. This study evaluated a strategy of decreased protamine dosing in OPCAB.
Methods: Eighty consecutive OPCAB patients who underwent surgery performed by a single surgeon at a single institution over a 12-month period were retrospectively analyzed. Patients underwent a mean of 2.91 +/- 0.1 OPCAB grafts with full heparinization and 50% of the calculated protamine dose was administered. ACT, partial thromboplastin times, thoracostomy tube outputs, transfusions, and clinical outcomes were assessed.
Results: Of 80 patients, 76 (95%) returned to baseline ACT values with 50% protamine dosing. All patients demonstrated intraoperative clinical evidence of hemostasis. Mean 8- and 24-hour thoracostomy tube outputs were 424 +/- 24 mL and 806 +/- 38 mL, respectively. A mean of 1.7 +/- 0.2 packed red blood cell transfusions/patient was administered. There were no transfusions of platelets, fresh frozen plasma, or cryoprecipitate; no reexplorations; and no mortalities. Patients were discharged a mean of 4.4 +/- 0.1 days postoperatively.
Conclusion: A standard protamine dosing formula adequate for on-pump cardiac surgical procedures significantly overestimates protamine requirements for OPCAB. Patients treated with decreased protamine do not appear to have adverse outcomes.

Entities:  

Year:  2004        PMID: 14980850

Source DB:  PubMed          Journal:  Heart Surg Forum        ISSN: 1098-3511            Impact factor:   0.676


  1 in total

Review 1.  Optimal intraoperative anticoagulation strategy in patients undergoing off-pump coronary artery bypass.

Authors:  Sonia Rasoli; Mohamed Zeinah; Thanos Athanasiou; Antonios Kourliouros
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-02-03
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.