Tensile bond strength of different adhesive systems between bone and composite compared: an in vitro study.

Peter Maurer1, Katrin Bekes, Christian R Gernhardt, Hans-Günter Schaller, Johannes Schubert.   

Abstract

INTRODUCTION: The aim was to compare tensile bond strength of three dentine adhesive systems (Excite, Clearfil New Bond, Etch & Prime 3.0) and two cyanoacrylate adhesives (Cyano Veneer, Histoacryl) to animal bone in vitro.
MATERIAL AND METHODS: Specimens from five porcine mandibles (diameter 9 mm) with a total thickness of 4mm (+/-0.5mm) and a cortical layer of 1.5mm (+/-0.2mm) were prepared using trephine burs under constant water cooling and under standardized conditions. They were assigned to five experimental groups. Tensile bond strength of five different adhesive agents (Clearfil New Bond, Etch & Prime 3.0, Excite, Histoacryl and Cyano Veneer was measured 15 min after application and after light curing of a composite material (Tetric Ceram, colour A2) added thereupon using a universal testing machine. Qualitative control was performed by scanning electron microscopy, while examining loaded and unloaded specimens.
RESULTS: The measured tensile bond strength was as follows: Clearfil New Bond 8.00 MPa (+/-1.36 MPa), Etch & Prime 3.0 4.05 MPa (+/-1.52 MPa), Excite 2.96 MPa (+/-1.34 MPa), Histoacryl 5.22 MPa (+/-2.00 MPa), Cyano Veneer 4.56 MPa (+/-0.76 MPa). Clearfil New Bond showed significantly higher bond strength than the other four adhesives. Scanning electron microscopy analysis of unloaded specimens showed mixed modes of fracture. As regards the loaded specimens, no tag formation as known for dentine was found.
CONCLUSION: Within the limitations of an in vitro investigation it can be concluded that dentine adhesive systems might be useful for bone bonding. Tensile bond strength of the dentine adhesive systems tested on bone is comparable to that evaluated for dentine in earlier investigations.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14980587     DOI: 10.1016/j.jcms.2003.11.001

Source DB:  PubMed          Journal:  J Craniomaxillofac Surg        ISSN: 1010-5182            Impact factor:   2.078


  4 in total

1.  Treatment of tripod fracture of zygomatic bone by N-2-butyl cyanoacrylate glue fixation, and its effects on the tissues.

Authors:  Burhan Dadaş; Seyhan Alkan; Memet Cifci; Tülay Başak
Journal:  Eur Arch Otorhinolaryngol       Date:  2007-01-04       Impact factor: 2.503

2.  Adhesive strength of ethyl-2-cyanoacrylate tissue adhesive: how strong is it?

Authors:  Shih-Han Hung; Te-Ming Tseng; Hsin-Te Hsu; How Tseng
Journal:  Surg Today       Date:  2013-11-12       Impact factor: 2.549

3.  Comparison of failure mechanisms for cements used in skeletal luting applications.

Authors:  O Clarkin; D Boyd; M R Towler
Journal:  J Mater Sci Mater Med       Date:  2009-03-13       Impact factor: 3.896

4.  A new adhesive technique for internal fixation in midfacial surgery.

Authors:  Kira Endres; Rudolf Marx; Joachim Tinschert; Dieter Christian Wirtz; Christian Stoll; Dieter Riediger; Ralf Smeets
Journal:  Biomed Eng Online       Date:  2008-05-19       Impact factor: 2.819

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.