Literature DB >> 14980446

A method for studying insoluble immune complexes.

Boris N Khlebtsov1, Gennadii L Burygin, Larisa Yu Matora, Sergei Yu Shchyogolev, Nikolai G Khlebtsov.   

Abstract

Two variants of a method for determining the average composition of insoluble immune complex particles (IICP) are described. The first variant is based on measuring the specific turbidity (the turbidity per unit mass concentration of the dispersed substance) and the average size of IICP determined from dynamic light scattering (DLS). In the second variant, the slope of the logarithmic turbidity spectrum (wavelength exponent) is used instead of DLS particle size. Both variants allow the average biopolymer volume fraction to be determined in terms of the average refractive index of IICP. The method is exemplified by two experimental antigen+antibody systems: (i) lipopolysaccharide-protein complex (LPPC) of Azospirillum brasilense Sp245+rabbit anti-LPPC; and (ii) human IgG (hIgG)+sheep anti-hIgG. We have found that IICP can be modeled by incompact porous particles that contain about 30% of biopolymer substance and 70% of buffer.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14980446     DOI: 10.1016/j.bbagen.2003.12.005

Source DB:  PubMed          Journal:  Biochim Biophys Acta        ISSN: 0006-3002


  4 in total

1.  Effect of complement on sizes of model immune complexes.

Authors:  L B Korolevskaya; K V Shmagel
Journal:  Dokl Biochem Biophys       Date:  2014-11-04       Impact factor: 0.788

2.  Extracellular vesicles are associated with the systemic inflammation of patients with seropositive rheumatoid arthritis.

Authors:  Catalina Burbano; Mauricio Rojas; Carlos Muñoz-Vahos; Adriana Vanegas-García; Luis A Correa; Gloria Vásquez; Diana Castaño
Journal:  Sci Rep       Date:  2018-12-17       Impact factor: 4.379

3.  Sensor Based on PZT Ceramic Resonator with Lateral Electric Field for Immunodetectionof Bacteria in the Conducting Aquatic Environment.

Authors:  Irina Borodina; Boris Zaitsev; Andrey Teplykh; Gennady Burygin; Olga Guliy
Journal:  Sensors (Basel)       Date:  2020-05-25       Impact factor: 3.576

4.  Detection by Flow Cytometry of Anti-DNA Autoantibodies and Circulating DNA Immune Complexes in Lupus Erythematosus.

Authors:  Nisen Abuaf; Chantal Desgruelles; Mohamed Moumaris; Faïza Boussa-Khettab; Hidayeth Rostane; Emilie Bellec; Camille Frances
Journal:  J Immunol Res       Date:  2019-12-05       Impact factor: 4.818

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.