Literature DB >> 14979510

Effect of varying the pressurisation rate during noninvasive pressure support ventilation.

G Prinianakis1, M Delmastro, A Carlucci, P Ceriana, S Nava.   

Abstract

The aim of the study was to assess the effects of varying the pressurisation rate during noninvasive pressure support ventilation on patients' breathing pattern, inspiratory effort, arterial blood gases, tolerance to ventilation and amount of air leakage. A total of 15 chronic obstructive pulmonary disease patients recovering from an acute episode of hypercapnic acute respiratory failure were studied during four randomised trials with different levels of pressurisation rate. No significant changes were observed in breathing pattern and arterial blood gases between the different runs. The pressure time product of the diaphragm, an estimate of its metabolic consumption, was significantly lower with all pressurisation rates than with spontaneous breathing, but was significantly lowest with the fastest rate. However, air leak, assessed by the ratio between expired and inspired tidal volumes, increased and the patients' tolerance of ventilation, measured using a standardised scale, was significantly poorer with the fastest pressurisation rate. In chronic obstructive pulmonary disease patients recovering from an episode of acute hypercapnic respiratory failure and ventilated with noninvasive pressure support ventilation, different pressurisation rates resulted in different reductions in the pressure time product of the diaphragm; this reduction was greater with the fastest rate, but was accompanied by significant air leaks and poor tolerance.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14979510     DOI: 10.1183/09031936.03.00010203

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  15 in total

1.  Influence of ventilator settings on patient-ventilator synchrony during pressure support ventilation with different interfaces.

Authors:  R Costa; P Navalesi; G Spinazzola; G Ferrone; A Pellegrini; F Cavaliere; R Proietti; M Antonelli; G Conti
Journal:  Intensive Care Med       Date:  2010-05-26       Impact factor: 17.440

2.  Increased use of noninvasive ventilation in French intensive care units.

Authors:  Alexandre Demoule; Emmanuelle Girou; Jean-Christophe Richard; Solenne Taillé; Laurent Brochard
Journal:  Intensive Care Med       Date:  2006-06-24       Impact factor: 17.440

3.  Performance of noninvasive ventilation modes on ICU ventilators during pressure support: a bench model study.

Authors:  Laurence Vignaux; Didier Tassaux; Philippe Jolliet
Journal:  Intensive Care Med       Date:  2007-06-12       Impact factor: 17.440

4.  Real time noninvasive estimation of work of breathing using facemask leak-corrected tidal volume during noninvasive pressure support: validation study.

Authors:  Michael J Banner; Carl G Tams; Neil R Euliano; Paul J Stephan; Trevor J Leavitt; A Daniel Martin; Nawar Al-Rawas; Andrea Gabrielli
Journal:  J Clin Monit Comput       Date:  2015-06-13       Impact factor: 2.502

5.  Performance of noninvasive ventilation algorithms on ICU ventilators during pressure support: a clinical study.

Authors:  Laurence Vignaux; Didier Tassaux; Guillaume Carteaux; Jean Roeseler; Lise Piquilloud; Laurent Brochard; Philippe Jolliet
Journal:  Intensive Care Med       Date:  2010-08-06       Impact factor: 17.440

Review 6.  Bedside waveforms interpretation as a tool to identify patient-ventilator asynchronies.

Authors:  Dimitris Georgopoulos; George Prinianakis; Eumorfia Kondili
Journal:  Intensive Care Med       Date:  2005-11-09       Impact factor: 17.440

7.  Automatic adjustment of noninvasive pressure support with a bilevel home ventilator in patients with acute respiratory failure: a feasibility study.

Authors:  Anne Battisti; Didier Tassaux; David Bassin; Philippe Jolliet
Journal:  Intensive Care Med       Date:  2007-02-24       Impact factor: 17.440

8.  Helmet CPAP vs. oxygen therapy in severe hypoxemic respiratory failure due to pneumonia.

Authors:  Anna Maria Brambilla; Stefano Aliberti; Elena Prina; Francesco Nicoli; Manuela Del Forno; Stefano Nava; Giovanni Ferrari; Francesco Corradi; Paolo Pelosi; Angelo Bignamini; Paolo Tarsia; Roberto Cosentini
Journal:  Intensive Care Med       Date:  2014-05-10       Impact factor: 17.440

9.  Patient-ventilator asynchrony during non-invasive ventilation for acute respiratory failure: a multicenter study.

Authors:  Laurence Vignaux; Frédéric Vargas; Jean Roeseler; Didier Tassaux; Arnaud W Thille; Michel P Kossowsky; Laurent Brochard; Philippe Jolliet
Journal:  Intensive Care Med       Date:  2009-01-29       Impact factor: 17.440

10.  Neurally adjusted ventilatory assist (NAVA) improves patient-ventilator interaction during non-invasive ventilation delivered by face mask.

Authors:  Lise Piquilloud; Didier Tassaux; Emilie Bialais; Bernard Lambermont; Thierry Sottiaux; Jean Roeseler; Pierre-François Laterre; Philippe Jolliet; Jean-Pierre Revelly
Journal:  Intensive Care Med       Date:  2012-08-03       Impact factor: 17.440

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.