Literature DB >> 14978596

Correlation between oxygen consumption calculated using Fick's method and measured with indirect calorimetry in critically ill patients.

Flávio Marson1, Maria Auxiliadora Martins, Francisco Antonio Coletto, Antonio Dorival Campos, Anibal Basile-Filho.   

Abstract

OBJECTIVE: To compare the oxygen consumption index measured by using indirect calorimetry (VO2I Delta) with a portable metabolic cart and calculated according to Fick's principle (VO2 I Fick) in critically ill patients.
METHODS: Fourteen patients (10 men and 4 women, mean age 39.4 +/- 5.4 years) were analyzed, 5 of them trauma victims and 9 sepsis victims. The following mean scores were obtained for these patients: APACHE II = 21.3+/-1.8, ISS = 24.8+/-6, and sepsis score = 19.6+/-2.3. The mortality risk (odds ratio), calculated from APACHE II, was 41.9+/-7.1%. All patients underwent mechanical ventilation and invasive hemodynamic monitoring with a Swan-Ganz catheter. VO2 was obtained using the 2 methods (VO2I Delta and VO2I Fick) at 4 different times (T1-T4).
RESULTS: A good correlation was found between the 2 methods (r=0.77) for the mean of the 4 serial measurements. No statistically significant differences were observed between indirect calorimetry and Fick's equation at T1 (VO2I Delta = 138+/-28 and VO2I Fick = 59+/-38 mL.min-2.m-2, P=0.10) and T3 (VO2I Delta = 144+/-26 and VO2I Fick = 158+/-35 mL.min-2.m-2, P=0.14), but a significant difference was observed at T2 (VO2I Delta = 141+/-27 and VO2I Fick = 155+/-26 mL.min-2.m-2, P=0.03) and T4 (VO2I Delta = 145+/-24 and VO2I Fick = 162+/-26 mL.min-2.m-2, P=0.01).
CONCLUSION: We may state that indirect calorimetry can be used for oxygen consumption analysis in critically ill patients and is as efficient as Fick's reverse equation, with the benefit of being a noninvasive and risk-free procedure.

Entities:  

Mesh:

Year:  2004        PMID: 14978596     DOI: 10.1590/s0066-782x2004000100007

Source DB:  PubMed          Journal:  Arq Bras Cardiol        ISSN: 0066-782X            Impact factor:   2.000


  3 in total

1.  Comparison of oxygen consumption calculated by Fick's principle (using a central venous catheter) and measured by indirect calorimetry.

Authors:  Chiaki Inadomi; Yoshiaki Terao; Kazunori Yamashita; Makoto Fukusaki; Masafumi Takada; Koji Sumikawa
Journal:  J Anesth       Date:  2008-05-25       Impact factor: 2.078

Review 2.  Methodological Aspects of Indirect Calorimetry in Patients with Sepsis-Possibilities and Limitations.

Authors:  Weronika Wasyluk; Agnieszka Zwolak; Joop Jonckheer; Elisabeth De Waele; Wojciech Dąbrowski
Journal:  Nutrients       Date:  2022-02-22       Impact factor: 5.717

3.  Cutaneous Respirometry as Novel Technique to Monitor Mitochondrial Function: A Feasibility Study in Healthy Volunteers.

Authors:  Floor Anneleen Harms; Robert Jan Stolker; Egbert Gezinus Mik
Journal:  PLoS One       Date:  2016-07-25       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.